About Charging
Sequential 2-Stage Charging
In sequential charging mode the charger will check all battery banks every 15 minutes to determine which banks are present, healthy, and in most in need of charge. The bank most in need of charge will then be charged for the next 15 minutes.
The sequential charging mode employs the
Charging Overview
The XC Series will perform a battery detection sequence every 15 minutes, or on reapplication of AC, to determine which battery banks are present and healthy.
If you connect a battery when AC is disconnected, the remote will not recognize it until the unit has performed a battery detection with AC applied.
To force a battery detection sequence,
1.Turn off AC.
2.Wait approximately 20 seconds or until all lights on the charger or remote have gone out .
3.Turn on AC.
The charger will then perform a battery detection when AC is reapplied
The charger does not charge the banks in a