Indicator Light Flashing Sequences
975-0187-01-01 4–3
Indicator Light Flashing Sequences

Table 4-1

Indicator Light Sequences on the XCSeries

Activity Charger status
Charging indicator light illuminates The unit is charging in bulk or absorption mode
Charging indicator light flashes The unit is performing the equalization charge.
(Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every
four seconds if bank 2 is being equalized, and
three times every four seconds if bank 3 is being
equalized)
Ready indicator light illuminates The unit is either in float mode of three stage
charging or rest mode of two stage charging. All
batteries have been fully charged.
Fault indicator light illuminates Any fault condition that prevents the charge r from
charging one or more banks, but is not a charger
fault condition - remote display shows details of
fault. Example: (battery reverse
polarity detected)
Fault indicator light flashes Charger fault condition - remote display shows
followed by . The charger is damaged,
contact service.
Charging current indicator lights
illuminate These lights indicate the charging current. At
transition points when the current is changing, two
indicator lights may flash alternately, then settle
into the new charging curren t reading.
Charging current indicator lights
flash 100% indicator light flashes to indicate battery
temperature too high warning (> 50°C, 122 °F)
10% indicator light flashes to indicate battery
temperature too low warning (< 0°C, 32 °F)
25% indicator light flashes to indicate that a
battery has been disqualified (see page3–4)
Charging current indicator lights
flash,
Fault indicator light illuminated
100% indicator light flashes to indicate battery
temperature too high fault (> 55°C, 131 °F)
10% indicator light flashes to indicate battery
temperature too low fault (< -20°C, -4 °F)
XC_Charger_Owner.book Page 3 Friday, August 12, 2005 3:23 PM