Indicator Light Flashing Sequences
Indicator Light Flashing Sequences
Table 4-1 Indicator Light Sequences on the XC Series
| Activity | Charger status |
|
|
|
|
|
|
| ||
| Charging indicator light illuminates | The unit is charging in bulk or absorption mode | |||
|
|
|
| ||
| Charging indicator light flashes | The unit is performing the equalization charge. | |||
|
| (Charging indicator light flashes once every four | |||
|
| seconds if bank 1 is being equalized, twice every | |||
|
| four seconds if bank 2 is being equalized, and | |||
|
| three times every four seconds if bank 3 is being | |||
|
| equalized) |
|
|
|
|
|
|
| ||
| Ready indicator light illuminates | The unit is either in float mode of three stage | |||
|
| charging or rest mode of two stage charging. All | |||
|
| batteries have been fully charged. | |||
|
|
|
| ||
| Fault indicator light illuminates | Any fault condition that prevents the charger from | |||
|
| charging one or more banks, but is not a charger | |||
|
| fault condition - remote display shows details of | |||
|
| fault. Example: |
| (battery reverse | |
|
| err | ErrCHfBATPoL | ||
|
| polarity detected) |
|
| |
| Fault indicator light flashes | Charger fault condition - remote display shows | |||
|
| followed by | . The charger is damaged, | ||
|
| contact service. |
|
|
|
| Charging current indicator lights | These lights indicate the charging current. At | |||
| illuminate | transition points when the current is changing, two | |||
|
| indicator lights may flash alternately, then settle | |||
|
| into the new charging current reading. | |||
| Charging current indicator lights | 100% indicator light flashes to indicate battery | |||
| flash | temperature too high warning (> 50 °C, 122 °F) | |||
|
| 10% indicator light flashes to indicate battery | |||
|
| temperature too low warning (< 0 °C, 32 °F) | |||
|
| 25% indicator light flashes to indicate that a | |||
|
| battery has been disqualified (see page | |||
|
|
|
| ||
| Charging current indicator lights | 100% indicator light flashes to indicate battery | |||
| flash, | temperature too high fault (> 55 °C, 131 °F) | |||
| Fault indicator light illuminated | 10% indicator light flashes to indicate battery | |||
|
| temperature too low fault (< | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|