Problem Solving
Symptom
The XC Series appears to be taking too long to charge battery. Ready indicator light does not illuminate after 24 hours of charging.
Possible Cause | Solution |
|
|
Battery capacity is too high for the | Use a higher capacity charger. |
XC Series model. |
|
Load connected to battery is | Disconnect load or switch load off. |
draining charge current so that |
|
battery does not recharge. |
|
Battery has a damaged cell.
Replace battery.
Symptom
The XC Series will not transition to equalization mode.
| Possible Cause | Solution |
|
|
|
|
|
| |||
| Battery is the wrong type, or set to | Verify battery type is set to Gel or AGM. These | |||
| the wrong type to equalize. | battery types cannot be equalized. |
|
| |
| Not all batteries are fully charged. | Wait for all batteries to be in float ( | ) of | ||
|
| charging or rest ( | ) of | ||
|
| attempting to equalize (the ready indicator light will | |||
|
| illuminate). |
|
|
|
| An active fault is present on the | Clear the active fault (see Table | |||
| bank you are attempting to equalize. |
| rdy | flo |
|
|
|
|
| ||
|
|
|
| ||
|
|
|