
Operation
Equalizing Flooded Batteries
About Equalizing
The XC Series equalizes only flooded
In the following conditions the remote display will show and the XC Series will not enter equalization mode:
•
• any battery is not fully charged (all three battery banksnomust be charged to float or rest stage before equalization can be activated on any bank)
• there is an active fault on the battery you are trying to charge
Xantrex recommends that you run a normal charge cycle on the batteries before you equalize them.
During equalization, the battery generates explosive gases. Follow all the battery safety precautions listed in this guide. Ventilate the area around the battery thoroughly and ensure that there are no sources of flame or sparks in the vicinity
The XC Series cannot automatically determine when to stop the equalization of a battery. You must monitor the battery specific gravity throughout equalization to determine the end of the equalize cycle. The one hour