Troubleshooting
4–6 975-0187-01-01
Green 100% indicator light
flashes
Display green bank indicator
light for the affected battery
bank illuminated
Battery too
Hot Warning Allow battery to cool. Improve ventilation
or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss. If the te mperature
increases, the XC Series will enter th e
fault level and stop charging the affected
bank.
Red fault indicator light
illuminated
Green 100% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated
Battery too
Hot Shutdown Allow battery to cool. Improve ventilation
or install in cooler location. It may
indicate a shorted cell in the battery or
excessive water loss.
Cannot apply
change The operation you have tried to execute
cannot be completed.
Red fault indicator light
illuminated No batteries
detected The charger did not detect any batteries.
Table 4-2
Error Messages
Display Onboard Status Panel
Indicator lights Fault Solution