Troubleshooting

Table 4-2Error Messages

 

Onboard Status Panel

 

 

Display

Indicator lights

Fault

Solution

 

 

 

 

Hot

Green 100% indicator light

Battery too

Allow battery to cool. Improve ventilation

flashes

Hot Warning

or install in cooler location. It may

 

 

Display green bank indicator

 

indicate a shorted cell in the battery or

 

light for the affected battery

 

excessive water loss. If the temperature

 

bank illuminated

 

increases, the XC Series will enter the

 

 

 

fault level and stop charging the affected

 

 

 

bank.

 

 

 

 

Err

Red fault indicator light

Battery too

Allow battery to cool. Improve ventilation

illuminated

Hot Shutdown

or install in cooler location. It may

Ht

Green 100% indicator light

 

indicate a shorted cell in the battery or

 

 

 

flashes

 

excessive water loss.

 

Display green bank indicator

 

 

 

light for affected battery bank

 

 

 

illuminated

 

 

 

 

 

 

 

 

Cannot apply

The operation you have tried to execute

no

 

change

cannot be completed.

 

 

 

 

Err

Red fault indicator light

No batteries

The charger did not detect any batteries.

illuminated

detected

 

 

 

Bat

 

 

 

 

 

 

4–6

 

 

975-0187-01-01

Page 64
Image 64
Xantrex Technology XC5012, XC2524, XC3012, XC1524 manual Bat