Access Code Programming
In addition to the Master Access Code, you can program up to 16 additional User Access codes. Press
, plus your Master Access Code, the armed ( ) indicator will turn on.
Enter the
Access Code) or use the keys to find the specific code and press to select. Enter the new 4
to exit.
The access codes have programmable attributes which allow zone bypassing, duress, supervisor or
Access Codes
[ ][5][Master Code] (when disarmed)
The [ ][5] User’s Programming command is used to program additional access codes.
User Codes - User Codes
Master Code (Access Code 40) - The Master Code has all of the attributes listed in the Program- mable Attributes list below except for Duress (2) and One Time Use (8) and is required to program all Supervisor Code attributes.
Supervisor Codes - These codes are always valid when entering the User Code Program- ming section. However, these codes can only program additional codes which have equal or lesser attributes. Once programmed, the Supervisor Codes receive the Master Code’s attributes. These attributes are changeable. Any User Code can be made a supervisor code by enabling User Code Attribute 1 (please see below for details).
Duress Codes - Duress codes are standard User Codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system. Any User Code can be made a Duress Code by enabling User Code Attribute 2 (please see below for details).
One Time Use Code - This code permits temporary access to the system for a 24 Hr. time period. During the 24 Hr. period, the temporary user may disarm the system once. There is no restriction on the number of times the temporary user may arm the system during the time period.
NOTE: Duress codes are not valid when entering [ ][5], [ ][6] or [ ][8] sections.
NOTE: Access codes cannot be programmed as a duplicate or as a “Code +/- 1”.
User Code Attributes
1.The default attributes of a new code will be the attributes of the code used to enter whether it is a new code or an existing code being programmed.
2.System Master (Code 40) has Attribute 3 ON by default.
NOTE: These attributes are not changeable.
Inherent Attributes (all codes except installer)
Arm / Disarm - Any Access Code will be valid for arming and disarming the system.
Command Outputs ([ ][7][1] and [ ][7][2]) - If these outputs require Access Code entry, any Access Code is valid for performing the [
Programmable Attributes ([ ][5][Master/Supervisor Code [9][Code])
1Supervisor Code
2Duress Code
3Zone Bypassing Enabled
7Bell Squawk upon Away Arming/Disarming
8One Time Use Code
Zone Bypassing Attribute
This attribute allows the User to manually bypass zones if Bypassing requires an access code.
7