ADT Security Services SCW9047-433 manual Viewing the Event Buffer, Testing Your System, Walk Test

Models: SCW9047-433 SCW9045-433

1 20
Download 20 pages 9.36 Kb
Page 13
Image 13
Viewing the Event Buffer

2.Use the Testing Your SystemSounder and Display Test keys to scroll to Buzzer Control.

3.There are 21 different levels, use the Walk TestAllowing Computer Access To Your System keys to scroll to the desired level.

Viewing the Event Buffer

The event buffer will show you a list of the last 128 events that have occurred on your system.

1.Press Manual backgroundManual background [Master Code].

2.To select Event Buffer viewing, press Manual background .

3.The keypad will display the event number and the time and date. Press Manual background to switch between this information and the event details.

4.Use the Manual backgroundManual backgroundManual background keys to scroll through the events in the buffer.

5.To exit event buffer viewing, press Manual background .

Testing Your System

NOTE: Inform your Monitoring Station when you begin and end System Testing.

All smoke detectors in this installation must be tested by your smoke detector installer or dealer once a year to ensure they are functioning correctly. It is the user’s responsibility to test the system weekly (excluding smoke detectors). Ensure you follow all the steps in the two tests below.

NOTE: Should the system fail to function properly, call your installation company for service im- mediately.

Sounder and Display Test

This Test activates all display pixels and indicator lights and does a four second check of the sounder.

1.Press Manual backgroundManual background [Master Code] Manual background .

2.The following will occur:

-The system activates the Bell output on medium volume for 2 seconds followed by full volume alarm for 2 seconds. All display lights and LCD pixels will turn ON.

-The Ready, Armed, Trouble and Power LED’s will flash for the duration of the test

3.To exit the function menu, press Manual background .

Walk Test

Walk Test mode allows you test the operation of each detector in the system. While in Walk Test mode, the Ready, Armed, and Trouble LED's will flash to indicate that the Walk Test is active. The

Walk Test can be terminated at anytime by re-entering Manual backgroundManual background [Master code] 8 on the keypad.The system will also automatically terminate the Walk Test on completion, it will annunciate with an audi- ble warning (5 beeps every 10 seconds), beginning five minutes before the termination of the test.

1.Before testing, ensure that the system is disarmed and the Ready light is on.

2.Press Manual background and close all zones to return the system to the Ready state.

3.Perform a System Test by following the steps in the previous section.

4. Press

[Master code] 8 to initiate the Walk Test

5.To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion detector areas).

The System will display the following message when each zone (detector) is activated: “Secure

System Before Arming < >”, “Secure System or Enter Code” or “Secure or Arm System”. Use the

Manual backgroundManual backgroundManual background keys to view which zones are open. The message will disappear when the zones are closed.

Allowing Computer Access To Your System

From time to time, your installer may need to send information to or retrieve information from your security system. Your installer will do this by having a computer call your system over the telephone line. You may need to prepare your system to receive this ‘downloading’ call. To do this:

Press Manual backgroundManual background [Master code] Manual background at the keypad. This allows downloading for a limited period of time. During this time, the system will answer incoming downloading calls.

For more information on this feature, please ask your installer.

9

Page 13
Image 13
ADT Security Services SCW9047-433 manual Viewing the Event Buffer, Testing Your System, Sounder and Display Test, Walk Test