ETH 0/1 Ethernet port located on the rear of the unit.
3.Enter ip address 10.3.0.151 255.255.255.0 to assign an IP address to the Ethernet port using
4.Enter no shutdown to activate the interface to pass data.
5.Enter exit to exit the interface commands and return to the Global configuration mode.
Depending on your configuration, you may need to set a default gateway as well as using the (config)#ip default gateway command. If IP routing is enabled on the unit, do NOT set a default gateway.
Then enable Web interface access using the following configuration:
Web Access
Switch>
Switch>
Switch>en
Password:
Switch#conf t
Switch(config)#ip http server
Telnet configuration is not necessary but is recommended, use the following commands to enable Telnet access:
Telnet Configuration
Switch>
Switch>
Switch>en
Password: adtran
Switch#conf t
Switch(config)#line telnet 0 4
Note: Telnet and Web access require a static IP address or DHCP configured IP address. If accessing from a different subnet, routing configuration will be required.
Web User Interface
Using your preferred Web browser navigate to the Adtran Total Access product Web interface GUI, using the IP address configured earlier via the CRAFT port, using the following syntax:
HTTP://10.3.0.151
You will be prompted with a login window:
960 Stewart Drive Sunnyvale, CA 94085 USA Phone +1.408.331.3300 +1.877.80SHORE Fax +1.408.331.3333 www.ShoreTel.com
- 12 -