Examples:

A new I35MB is installed in the field with two 20GB capacity media for 20GB of mirrored storage. Bank 1 requires replacement. A 10GB media is installed and the button pressed for rebuild. Rebuild will not start and the mirror remains broken.

A 40GB media is then inserted in Bank 1. The rebuild copies the data from the Bank 0 20GB drive to the new drive in Bank 1. The I35MB remains a 20GB mirrored device.

Bank 0 media is replaced with a 60GB unit. The rebuild copies the operational 20GB from Bank 1. The I35MB now has a 40GB media in the Bank 1 and a 60GB drive in Bank 0. The I35MB remains a 20GB mirrored device.

Contact Adtron Technical support for more information regarding using different size media.

Aborting a button press

If the bank button is pressed for longer than 20 seconds, no operation is performed. This is provided as an opportunity to abort a button press.