Mirror Control Button Functions

Adtron I35MB Operations Manual

Mirror Control Button Functions

The following figure shows the location of the mirror control buttons and LEDs on the I35MB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Buzzer Reset

Bank 1 Mirror control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bank 0 Mirror control

Figure 8 Mirror Control Button operations

The following table describes the different operations using the Mirror Control button on either bank. Press and hold Mirror Control button to activate the functions listed in Table 2.

Button Press Duration

Bank Access LED Feedback

Function

 

 

 

 

0

– 5 seconds

LED flashes slow (1/sec)

Power up or down bank

5

– 10 seconds

LED flashes medium (2/sec)

Mirror Rebuild

10 – 15 seconds

LED flashes fast (4/sec)

No Operation

15 – 20 seconds

LED solid on

Reserved

> 20 seconds

LED off

No Operation

Table 2 Mirror Control Button operations

Functions marked reserved are for Adtron factory use only. Contact technical support for more details. In the case of a button press duration that reaches 15 seconds, DO NOT release until after 20 seconds to save future operations.

Advanced Operations

The individual banks may be taken off-line (powered down and/or replaced) at any time, for preventative maintenance or due to a failure. However, taking a bank offline automatically faults the mirror, requiring a rebuild. To clear a hard or soft fault, the rebuild must complete.

Managing Faults

The I35MB has two fault indicators: hard and soft. Refer to page 19, for the specific bank fault LED indicators to interpret these two types of faults.