Adtron I35MB Operations Manual
Mirror Control Button Functions
The following figure shows the location of the mirror control buttons and LEDs on the I35MB.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Buzzer Reset | Bank 1 Mirror control | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bank 0 Mirror control
Figure 8 Mirror Control Button operations
The following table describes the different operations using the Mirror Control button on either bank. Press and hold Mirror Control button to activate the functions listed in Table 2.
Button Press Duration | Bank Access LED Feedback | Function | |
|
|
|
|
0 | – 5 seconds | LED flashes slow (1/sec) | Power up or down bank |
5 | – 10 seconds | LED flashes medium (2/sec) | Mirror Rebuild |
10 – 15 seconds | LED flashes fast (4/sec) | No Operation | |
15 – 20 seconds | LED solid on | Reserved | |
> 20 seconds | LED off | No Operation |
Table 2 Mirror Control Button operations
Functions marked reserved are for Adtron factory use only. Contact technical support for more details. In the case of a button press duration that reaches 15 seconds, DO NOT release until after 20 seconds to save future operations.
Advanced Operations
The individual banks may be taken
Managing Faults
The I35MB has two fault indicators: hard and soft. Refer to page 19, for the specific bank fault LED indicators to interpret these two types of faults.
8 | Rev. 003, PN: 610200094 |