2 – Date and Time

ICP-CC404 Installation Guide 4.0 System Operations

2 – Date and Time

The date and time fault occurs every time power is removed from the control panel. This type of fault causes the FAULT indicator to flash only if the Auto Arming Time is programmed in Locations 414 to 417 (refer to Section 17.12 Auto Arming Time on page 72). If this timer is not programmed, a date and time fault is indicated only when you enter Fault Analysis Mode. This fault clears after you program the date and time. Refer to Section 6.2.7 Setting the Date and Time on page 36 for more information.

3 – Sensor Watch

A sensor watch fault occurs when one of the detection devices stops working or fails to detect movement during the programmed time period when the system is disarmed. The sensor watch fault clears after the registered zone is unsealed and resealed.

To determine the zone that registered the sensor watch fault:

1.In Fault Analysis Mode, press and hold [5]. The indicator for the faulted zone lights.

2.Release the button.

Program the Sensor Watch Time in Locations 408 and 409 (refer to Section 17.7 Sensor Watch Time on page 71). To select the zones to be monitored for sensor watch, refer to Section 14.3.4 Zone Options 1 on page 57.

When reporting to the base station receiver, the control panel sends a Self Test Fail Report (Contact ID Event Code 307) to indicate the sensor watch fault.

4 – Horn Speaker Monitor

A horn speaker monitor fault occurs when the horn speaker is disconnected from the control panel. This fault clears when the horn speaker is reconnected. To enable monitoring of the horn speaker, select Option 2 in Location 424 (refer to Section 18.1 System Options 1 on page 73).

5 – Telephone Line Fault

A telephone line fault occurs when the telephone line disconnects from the control panel for longer than 40 sec. This fault can only occur if Option 1 is selected in Location 176 (refer to Section 11.11 Telephone Line Fault Options on page 49). The fault clears when the telephone line reconnects for longer than 40 sec.

6 – EEPROM Fail

An EEPROM Fail is registered when the control panel detects an internal checksum error. You must remove power to the control panel and reset the control panel to default values to clear this fault.

7 – AUX Power Supply Fail

This fault occurs when either the 1 A, 12 V accessories AUX power supply or the 1 A codepad AUX power supply fails. Ten sec after the AUX power supply fails, the control panel automatically sends a System Trouble code (Contact ID Event Code 300) to the base station receiver. Ten sec after the PTC is reset, the control panel sends a Trouble Restore Report.

If both 1 A AUX power supplies fail, only one system Trouble Report is sent to the base station receiver. The Trouble Restore Report is sent only after both AUX power supplies are reset.

8 – Communication Failure

A communication failure fault is registered if calls to the primary and secondary telephone numbers for Receiver 1 or Receiver 2 are unsuccessful.

To determine which receiver failed to report:

1.In Fault Analysis Mode, press and hold [8]. Two beeps sound.

2.Release the button.

If Receiver 1 failed to report, the Zone 1 indicator lights. If Receiver 2 failed to report, the Zone 2 indicator lights.

If the primary and secondary telephone numbers for Receiver 1 or Receiver 2 are set up for base reporting, Receiver 1 and Receiver 2 can each try up to twelve calls, per event, to the base station receiver. If the primary and secondary telephone numbers are programmed for both Receiver 1 and Receiver 2, the two receivers together can try up to 24 calls if the event is programmed to report on both receivers.

The control panel tries to call the base station receiver up to six times using both the primary and secondary telephone numbers (three times if only the primary telephone number is programmed). If the control panel fails to communicate to the base station receiver, a communications fault occurs. The control panel waits 10 min before it tries to report to the base station receiver up to six more times. The communication fault resets after the next successful call.

If Receiver 1 or Receiver 2 is programmed for domestic reporting, the control panel does not show a fault if it fails to report after calling six times.

If Option 1 in Location 145 is enabled (refer to Section 12.1 Dialer Options 1 on page 50) and no telephone numbers are programmed, no fault occurs.