15.18System Status – Low Battery Restore Report

ICP-CC404 Installation Guide 15.0 System Reporting Information

A Battery Test Failure Report (Contact ID Event Code 309) is sent to the base station receiver when the system’s battery voltage falls below 11.2 VDC or when a dynamic battery test detects that a low capacity battery.

The control panel continually monitors the battery voltage. Refer to Section 4.13 Fault Descriptions on page 22 for more information. A dynamic battery test is performed every time the system is armed and every four hours after the control panel is powered up.

If Low Battery Reports are not required, program Locations 352 and 353 as 0.

Outputs 1 to 4 do not operate when the control panel detects a low battery.

15.18System Status – Low Battery Restore Report

Program the Low Battery Restore Report value in Location 354 (tens digit) and Location 355 (units digit).

The default values are 10 (tens) and 6 (units).

A Low Battery Restore Report is sent if the backup battery is restored the next time the system is armed, or when the next dynamic battery test reports the battery test is OK.

If Low Battery Restore Reports are not required, program Locations 354 and 355 as 0.

15.19 System Status – Access Denied

Program the Code Retry Limit in Location 356. The default value is 6.

Program 0 to allow unlimited retries.

Program the Access Denied Report value in Location 357 (tens digit) and Location 358 (units digit).

The default values are 7 (tens) and 12 (units).

An Access Denied Report (Contact ID Event Code

421)is sent to the base station receiver when the number of incorrect code attempts equals the number programmed in Location 356. An Access Denied Alarm is audible, but you can program the alarm as silent by selecting Option 8 in Location 425 (refer to Section 18.2 System Options 2 on page 73).

Restore reports for this event are not sent.

If Access Denied reports are not required, program Locations 357 and 358 as 0.

Code Retries

The Code Retries feature restricts the number of times an invalid User Code can be entered in an attempt to operate the system. Location 356 sets the number of incorrect code attempts that causes an alarm. When the number of incorrect code attempts equals the number programmed in this location, the system performs these actions:

Activates the sirens, internal screamers, and strobes connected to the control panel. Select Option 8 in Location 425 (refer to Section 18.2 System Options 2 on page 73) to change this alarm to silent.

Shuts down all codepads connected to the control panel and locks them out for the time period programmed in Location 410 (refer to Section 17.8 Codepad Lockout Time on page 71).

Sends an Access Denied Report (Contact ID Event Code 421) to the base station receiver.

Each time the system is armed or disarmed, the Code Retries counter is reset. You can program the counter to a value from 1 to 15. If you want the number of incorrect code attempts to be unlimited, program a 0 in Location 356. In this case, the Access Denied Report is never generated and the system does not perform the three actions listed above. This function works when the system is armed or disarmed.

15.20 System Status Reporting Options

Use Location 359 to select whether System Status Reports are sent to Receiver 1 (the default), Receiver 2, or both, Receiver 2 only when Receiver 1 fails, or there is no reporting at all. Table 47 lists the reporting options.

Table 49: System Status Reporting Options

Option Description

0No System Status Reports required

1

Receiver 1

2

Receiver 2

 

 

4Receiver 1 and Receiver 2

8Receiver 2 only when Receiver 1 fails

15.21 Test Reporting Time