ICP-CC404 Installation Guide 17.0 System Event Timers
The Siren Sound Rate varies the frequency of the siren tone slowest (0) and to fastest (15). The Siren Sound Rate does not change the frequency of the fire alarm tone.
17.11 Auto Arming Pre-Alert Timer
Program the Auto Arming
The default value for the Auto Arming
This location sets the time period during which the control panel warns you it is automatically armed in AWAY Mode. The codepad beeps once every second until the
After the control panel automatically arms in AWAY Mode or STAY Mode 1, Exit Time starts. If a valid User Code is entered during the
If you want a programmable output to operate during the Auto Arming
17.12 Auto Arming Time
Program the Auto Arming Time in Locations 414 to
417as described in Table 58.
The default value is midnight (0 0 0 0).
Table 58: Auto Arming Time Parameters
|
|
|
Location | Parameter | Default |
414 | Hour of day (tens digit) | 0 |
415 | Hour of day (units digit) | 0 |
|
|
|
416 | Minute of day (tens digit) | 0 |
417 | Minute of day (units digit) | 0 |
|
|
|
These locations specify the time of the day that the system automatically arms itself in AWAY Mode. Set this time in
If forced arming is disabled for any zone, the automatic arming feature operates regardless of whether any zones are unsealed. Refer to Section
14.3.6Zone Options 2 on page 58 for more information on programming zones for forced arming.
User Code 16 is reported when this feature is used.
17.13 Auto Disarming Time
Program the Auto Disarming Time in Locations 418 to 421 as described in Table 59.
The default value is midnight (0 0 0 0).
Table 59: Auto Disarming Time Parameters
|
|
|
Location | Parameter | Default |
418 | Hour of day (tens digit) | 0 |
419 | Hour of day (units digit) | 0 |
|
|
|
420 | Minute of day (tens digit) | 0 |
421 | Minute of day (units digit) | 0 |
|
|
|
These locations specify the time of day that the system automatically disarms itself. Set this time in
User Code 16 is reported when this feature is used.
17.14 Kiss-Off Wait Time
Program the
The default value for the
This location sets the time that the control panel waits for acknowledgment before resending a report. This timer applies only to the 4 + 2 Express Format.
17.15 System Time
Program the System Time in Locations 901 to 904 as described in Table 60.
The default value is 0 0 0 0.
Table 60: System Time Parameters
|
|
|
Location | Parameter | Default |
901 | Hour of day (tens digit) | 0 |
902 | Hour of day (units digit) | 0 |
903 | Minute of day (tens digit) | 0 |
904 | Minute of day (units digit) | 0 |
The
A Master Code holder can also set the System Date and Time (refer to Section 6.2.7 Setting the Date and Time on page 36).
17.16 System Date
Program the System Date in Locations 905 to 910 as described in Table 61.
The default value is 01 January, 2001 (0 1 0 1 0 1).
72 | Bosch Security Systems, Inc. 12/08 |