To add or change a remote radio User Code:
1.Enter the Master Code and press [1][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.
2.Enter the user number (9 to 16) you want to add or change and press [AWAY].
Two beeps sound and the corresponding zone indicators light. Refer to Table 17.
Table 17: Codepad Indicators for Remote Radio User Numbers
Data |
|
| Zone Indicators |
|
|
| |||
Value | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | MAINS |
9X X
10 |
|
|
|
|
|
| X |
11 | X |
|
|
|
|
| X |
12 |
| X |
|
| X | ||
|
|
|
|
|
|
| |
13 |
|
| X |
|
|
| X |
14 |
|
|
| X |
|
| X |
|
|
|
|
|
|
| |
15 |
|
|
|
| X |
| X |
16 |
|
|
|
|
| X | X |
3.Press any of the [TRANSMIT] buttons on the
Two beeps sound and the STAY and AWAY indicators turn off.
4.Repeat Steps 1 through 3 to add or change another remote radio User Code.
This function ends automatically if you do not press a button within 60 sec or if you press [AWAY].
One long beep indicates that the code already exists or you selected an incorrect user number.
To delete a remote radio User Code:
1.Enter the Master Code and press [1][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.
2.Enter the user number (9 to 16) you want to delete and press [AWAY].
Two beeps sound and the corresponding zone indicators light. Refer to Table 17.
3.Press [STAY] to delete the User Code.
Two beeps sound and the STAY and AWAY indicators turn off.
4.Repeat Steps 1 through 3 to delete another remote radio User Code.
This function ends automatically if you do not press a button within 60 sec or if you press [AWAY].
One long beep indicates that you selected an incorrect user number.
5.4Two-Channel Remote Radio Hand- Held Transmitter Operations
Because all operations using the
Figure 4: RE012/E: 2-Channel Keyfob Transmitter
1 | 2 |
3
1 – Button 1: Arm or disarm in AWAY Mode
2 – Button 2: Arm or disarm STAY Mode
3 – Buttons 1 and 2: Press both buttons at the same time to activate Panic alarm.
5.4.1Arming in AWAY Mode
Press and hold the black button for 2 sec.
Two beeps sound on the remote codepad and the AWAY indicator lights. Exit Time starts.
If horn speaker indication beeps are enabled, two beeps sound from the horn speaker. If strobe indications are enabled, the strobe flashes for 6 sec to indicate the system is armed.
5.4.2Disarming from AWAY Mode
Press and hold either the black or green button for 2 sec.
Two beeps sound on the remote codepad and the AWAY indicator turns off.
If horn speaker indication beeps are enabled, one beep sounds from the horn speaker. If strobe indications are enabled, the strobe flashes for 3 sec to indicate the system is disarmed.
5.4.3Arming in STAY Mode 1
Press and hold the green button for 2 sec.
Two beeps sound on the remote codepad and the STAY indicator lights. Exit Time starts.