ICP-CC404 Installation Guide 3.0 Codepad Indicators
Table 12: | FAULT Indicator | |
|
|
|
|
|
|
Indicator |
| Definition |
|
|
|
On |
| A system fault must be corrected |
Off |
| The system is normal (no faults) |
Flashing |
| A system fault must be acknowledged |
Audible Indicators
The codepad provides these audible indications:
Table 13: Audible Indicators
|
|
Audible Indicator | Definition |
|
|
One short beep | A button was pressed on the |
| codepad, or Exit Time ended when |
| arming in STAY Mode 1 or STAY |
| Mode 2 |
Two short beeps | The system accepted the code |
Three short beeps | The system executed the requested |
| function |
One long beep | Exit Time ended when arming in |
| AWAY Mode, or the requested |
| operation was denied or aborted |
One short beep | Walk Test Mode is currently active, |
every second | or warning before automatic arming |
| takes place |
One short beep | Telephone Monitor Mode is active. |
every 2 sec |
|
One short beep | There is a system fault to |
every minute | acknowledge |
3.2ICP-CP508LW Eight Zone LCD Codepad
Figure 2: ICP-CP508LW Eight Zone LCD Codepad
The codepad is the communications interface between you and the alarm system. The codepad allows you to issue commands and offers visual and audible indications to guide you through general operation.
The codepad uses a number of indicators: eight zone indicators show the condition of each zone and seven other indicators show general status. These indicators are described in this section.
Zone Indicators
1 2 3 … The zone indicators (1 to 8) show the status of the zones as listed in Table 8 on page 16.
AWAY Indicator
The AWAY indicator lights when the system is armed in AWAY Mode. The ON indicator also lights when the system is armed in AWAY Mode (refer to Table 10 on page 16).
The AWAY indicator flashes with the STAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.
Refer to Section 4.1 Arming the System in AWAY Mode on page 18 for more information.
STAY Indicator
The STAY indicator lights when the system is armed in STAY Mode 1 or STAY Mode 2 (refer to Table 9 on page 16).
The STAY indicator also flashes with the AWAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.
The ON indicator also lights when the system is armed in STAY Mode 1 or STAY Mode 2.
For more information, refer to:
•Section 4.3 on page 19 to arm the system in STAY Mode 1.
•Section 14.3.4 on page 57 to set zones to automatically isolate in STAY Mode 1.
•Section 4.5 on page 20 to arm the system in STAY Mode 2.
•Section 6.1.4 on page 30 to use the Installer Code to set zones to automatically isolate in STAY Mode 2.
•Section 6.2.5 on page 35 to use the Master Code to set zones to automatically isolate in STAY Mode 2.
System Disarmed
This indicator lights with the OFF indicator when the system is disarmed.
MAINS Indicator
The MAINS indicator shows when the systems AC MAINS supply is normal or failed (refer to Table 11 on page 16).
When programming in Installer’s Programming Mode or using a Master Code function, the MAINS indicator lights to indicate a location value from 10 to
15.The MAINS indicator represents the 10 digit, which is added to the value of the lit zone indicator (for example, if the value programmed in a location is 12, the MAINS and Zone 2 indicators light).