ICP-CC404 Installation Guide 3.0 Codepad Indicators

Table 12:

FAULT Indicator

 

 

 

 

 

 

Indicator

 

Definition

 

 

 

On

 

A system fault must be corrected

Off

 

The system is normal (no faults)

Flashing

 

A system fault must be acknowledged

Audible Indicators

The codepad provides these audible indications:

Table 13: Audible Indicators

 

 

Audible Indicator

Definition

 

 

One short beep

A button was pressed on the

 

codepad, or Exit Time ended when

 

arming in STAY Mode 1 or STAY

 

Mode 2

Two short beeps

The system accepted the code

Three short beeps

The system executed the requested

 

function

One long beep

Exit Time ended when arming in

 

AWAY Mode, or the requested

 

operation was denied or aborted

One short beep

Walk Test Mode is currently active,

every second

or warning before automatic arming

 

takes place

One short beep

Telephone Monitor Mode is active.

every 2 sec

 

One short beep

There is a system fault to

every minute

acknowledge

3.2ICP-CP508LW Eight Zone LCD Codepad

Figure 2: ICP-CP508LW Eight Zone LCD Codepad

The codepad is the communications interface between you and the alarm system. The codepad allows you to issue commands and offers visual and audible indications to guide you through general operation.

The codepad uses a number of indicators: eight zone indicators show the condition of each zone and seven other indicators show general status. These indicators are described in this section.

Zone Indicators

1 2 3 … The zone indicators (1 to 8) show the status of the zones as listed in Table 8 on page 16.

AWAY Indicator

The AWAY indicator lights when the system is armed in AWAY Mode. The ON indicator also lights when the system is armed in AWAY Mode (refer to Table 10 on page 16).

The AWAY indicator flashes with the STAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.

Refer to Section 4.1 Arming the System in AWAY Mode on page 18 for more information.

STAY Indicator

The STAY indicator lights when the system is armed in STAY Mode 1 or STAY Mode 2 (refer to Table 9 on page 16).

The STAY indicator also flashes with the AWAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.

The ON indicator also lights when the system is armed in STAY Mode 1 or STAY Mode 2.

For more information, refer to:

Section 4.3 on page 19 to arm the system in STAY Mode 1.

Section 14.3.4 on page 57 to set zones to automatically isolate in STAY Mode 1.

Section 4.5 on page 20 to arm the system in STAY Mode 2.

Section 6.1.4 on page 30 to use the Installer Code to set zones to automatically isolate in STAY Mode 2.

Section 6.2.5 on page 35 to use the Master Code to set zones to automatically isolate in STAY Mode 2.

System Disarmed

This indicator lights with the OFF indicator when the system is disarmed.

MAINS Indicator

The MAINS indicator shows when the systems AC MAINS supply is normal or failed (refer to Table 11 on page 16).

When programming in Installer’s Programming Mode or using a Master Code function, the MAINS indicator lights to indicate a location value from 10 to

15.The MAINS indicator represents the 10 digit, which is added to the value of the lit zone indicator (for example, if the value programmed in a location is 12, the MAINS and Zone 2 indicators light).

Bosch Security Systems, Inc. 12/08 F01U089401-02

17

Page 17
Image 17
Bosch Appliances ICP-CC404 manual ICP-CP508LW Eight Zone LCD Codepad, Audible Indicators, System Disarmed