Bosch Appliances ICP-CC404 manual Access Code, 12.3Dialer Options, 12.4Alarm Link Options

Models: ICP-CC404

1 98
Download 98 pages 40.39 Kb
Page 51
Image 51
ICP-CC404  Installation Guide  13.0 Access Code

ICP-CC404 Installation Guide 13.0 Access Code

Open/Close Reports must be enabled in Locations 333 and 334 (refer to Section 15.6 Open/Close Reports on page 61) for this option to work.

4 – Delay Siren until Transmission Complete

If this option is selected, the EDMSAT, horn speaker, bell, and strobe outputs are not activated until after the control panel sends the message and the base station receiver sends a kiss-off back to the control panel. If multiple messages are sent, the sirens are activated after the last kiss-off is sent.

If a Codepad Panic, Codepad Fire, or Codepad Medical Alarm is activated, the EDMSAT, horn speaker, bell, and strobe outputs operate immediately.

8 – Extend Time to Wait for Handshake from 30 to 60 Sec

By default, the control panel waits approximately 30 sec for receipt of a valid handshake tone after it dials the monitoring station. The handshake tone indicates to the control panel that it reached the monitoring station and can now send its messages. Selecting this option extends this wait time from 30 sec to 60 sec.

12.3Dialer Options 3

Program the selected Dialer Options 3 in Location 179.

The default is 0. The options are:

1 – Set DTMF Dialing Pulses to 1 Digit/Sec

If this option is not selected, the Australian DTMF dialing format dials at 5 digits per sec (that is, 100 ms tone, 100 ms pause, 100 ms tone, 100 ms pause).

If this option is selected, the Australian DTMF dialing format dials at the rate of 1 digit per sec (that is, 500 ms tone, 500 ms pause).

2 – Reserved

4 – Change Decadic Dialing to 60/40

Some countries have different requirements for decadic dialing. Selecting this option changes the dialing characteristics from 65/35 (Australian Standard) to 60/40. Select this option only when the control panel is used in a country that requires decadic dialing as 60/40. This option has no effect when using DTMF tone dialing.

8 – Reserved

12.4Alarm Link Options

For more information about this location, refer to Section 8.2 Alarm Link Options on page 40.

13.0 Access Code

This section describes the access codes that assign privileges and access functions for User Code holders of the system. There are two types of access codes, the Installer Code and User Codes. Each code allows access and operation of control panel functions.

13.1Installer Code

Program the Installer Code in Locations 181 to 184.

The default Installer Code is 1 2 3 4.

Use this code to access Installer’s Programming Mode. The Installer Code can be up to four digits long. After power is applied to the control panel, the Installer Code can disarm the system if it is the first code used. The next time the Installer Code is used enables access to Installer’s Programming Mode.

Installer Code functions allow the installer to execute functions when the system is disarmed without the customer’s Master Code. Refer to Section 6.1 Installer Code Functions on page 27 for more information.

Refer to Section 2.1 Programming with the Remote Codepad on page 9 for more information on programming the system.

13.2User Codes

The purpose of User Codes is to arm and disarm the system and to perform other specific functions. A Master Code holder can change or delete User Codes.

Program User Codes 1 to 8 in Locations 185 to 224.

Program Remote Radio User Codes 9 to 16 in Locations 225 to 264.

The default User Codes are listed in Table 40.

Table 40: Default User Codes

 

 

 

 

 

 

 

User Number

Locations

Code

 

 

Priority

 

 

 

 

 

 

 

User #01

185 to 189

2

5

8

0

10

User #02

190 to 194

15

15

15

15

2

User #03

195 to 199

15

15

15

15

2

User #04

200 to 204

15

15

15

15

2

User #05

205 to 209

15

15

15

15

2

User #06

210 to 214

15

15

15

15

2

User #07

215 to 219

15

15

15

15

2

User #08

220 to 224

0

15 15

15

3

 

 

 

 

 

 

 

RF User #09

225 to 229

15

15

15

15

2

RF User #10

230 to 234

15

15

15

15

2

 

 

 

 

 

 

 

RF User #11

235 to 239

15

15

15

15

2

RF User #12

240 to 244

15

15

15

15

2

 

 

 

 

 

 

 

RF User #13

245 to 249

15

15

15

15

2

RF User #14

250 to 254

15

15

15

15

2

 

 

 

 

 

 

 

RF User #15

255 to 259

15

15

15

15

2

RF User #16

260 to 264

15

15

15

15

2

Bosch Security Systems, Inc. 12/08 F01U089401-02

51

Page 51
Image 51
Bosch Appliances ICP-CC404 Access Code, 12.3Dialer Options, 12.4Alarm Link Options, 13.1Installer Code, 13.2User Codes