Bosch Appliances manual 22.0, Programming Sheets, ICP-CC404| Installation Guide

Models: ICP-CC404

1 98
Download 98 pages 40.39 Kb
Page 86
Image 86
22.0

 

ICP-CC404 Installation Guide

22.0

Programming Sheets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

 

Options/Notes

 

 

 

Default/

 

 

Function

 

 

 

Programming Entry

 

 

 

 

 

 

 

 

175

0

Control panel does not answer

8

 

 

Ring Count

 

1 to 13 Number of rings until control panel answers

 

 

 

 

 

 

 

Refer to page 49

14

Answering machine bypass 2

 

 

 

 

 

 

 

 

15

Answering machine bypass 1

 

 

 

 

 

 

 

176

1

Display FAULT indicator when telephone line fails

0

 

 

Telephone Line Fail Options

2

Sound alarm when system arms

 

 

 

 

 

 

 

Refer to page 49

4

Sound alarm when system disarms

 

 

 

 

 

 

 

Options 2 and 4 must be used with Option 1 (for example, program 1, 3, 5, or 7).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

177

1

Dialer reporting functions allowed

9

 

 

Dialer Options 1

2

Remote arming by telephone allowed

 

 

 

 

 

 

 

Refer to page 50

4

Answering machine bypass only when armed

 

 

 

 

 

 

 

 

8

Bell 103 used for FSK format (Disabled = CCITT V21)

 

 

 

 

 

 

 

178

1

Open/Close Reports only if previous alarm

0

 

 

Dialer Options 2

2

Open/Close Reports for STAY Mode 1 and STAY Mode 2

 

 

 

 

 

 

 

Refer to page 50

4

Delay siren until transmission complete

 

 

 

 

 

 

 

 

8

Extend handshake wait time from 30 sec to 60 sec

 

 

 

 

 

 

 

179

1

Set DTMF dialing pulses to 1 digit/sec

0

 

 

Dialer Options 3

2

Reserved

 

 

 

 

 

 

 

Refer to page 51

4

Change decadic dialing to 60/40

 

 

 

 

 

 

 

 

8

Reserved

 

 

 

 

 

 

 

180

1

Upload/download allowed

3

 

 

Alarm Link Options

2

Call back phone number required for upload/download

 

 

 

 

 

 

 

Refer to page 40

4

Exit from upload/download connection on alarm

 

 

 

 

 

 

 

 

8

External modem module (CC811) required

 

 

 

 

 

 

 

181 to 184

 

 

 

 

1 2 3 4

 

 

Installer Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

Bosch Security Systems, Inc. 12/08 F01U089401-02