Bosch Appliances ICP-CC404 2.5Disable Factory Defaults, Using this feature is not recommended

Models: ICP-CC404

1 98
Download 98 pages 40.39 Kb
Page 15
Image 15
2.5Disable Factory Defaults

ICP-CC404 Installation Guide 2.0 Programming

2.5Disable Factory Defaults

Program the Disable Factory Defaults feature in Location 900.

The default value is 0.

This feature disables the DEFAULT button on the control panel printed circuit board (PCB) to prevent an operator from resetting the control panel to default values. This feature also prevents using a programming key when the system is disarmed.

Program 0 into this location to enable the DEFAULT button and to allow updates to location data using the programming key. Program 15 to disable the DEFAULT button and to require the Installer Code to program the control panel.

If the Installer Code is unknown, you must return the control panel to your Bosch Distributor for exchange. A nominal fee applies for this service.

Using this feature is not recommended.

If you need to disable the DEFAULT button, holding down the DEFAULT button on the PCB when programming this location prevents you from accidentally setting this option.

To prevent manual resetting of the control panel to default values:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the remote codepad shows the data programmed in Location 000.

If you are using the remote codepad, the STAY and AWAY indicators flash to indicate you entered Installer’s Programming Mode.

2.Enter [9 0 0 #] to move to Location 900.

3.Press and hold the DEFAULT button.

The DEFAULT button is located at the top of the PCB next to the PROGRAMMING KEY socket.

4.Enter [1 5 *] to program 15 into Location 900.

5.Release the button.

6.Enter [9 6 0 #] to exit from the Installer’s Programming Mode.

Two beeps sound and the system returns to the disarmed state. If you are using a remote codepad, the STAY and AWAY indicators turn off to indicate the system is disarmed.

If Location 900 is not programmed as 15, use one of these procedures to successfully reset the control panel to the factory default settings.

To reset the control panel using the Installer Code:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode.

Two beeps sound. The STAY and AWAY indicators flashes to indicate you entered Installer’s Programming Mode.

2.Enter [9 6 5 #].

Two beeps sound after the control panel is successfully reset.

3.Enter [9 6 0 #].

Two beeps sound. The STAY and AWAY indicators stop flashing and the system returns to the disarmed state.

The control panel is now successfully reset to the factory settings.

To reset the control panel using the default button:

1.Disconnect the AC MAINS supply and the backup battery from the control panel. Press and hold the DEFAULT button. The DEFAULT button is located at the top of the PCB next to the PROGRAMMING KEY socket.

2.Reconnect the AC MAINS supply to the control panel.

3.Wait 3 to 5 sec and release the button.

4.Enter [2 5 8 0 *] to disarm the system using the default Master Code.

The control panel is successfully reset to the factory settings.

If the option to restore the default control panel settings is disabled using Location 900:

The dialer seize relay (RL2) clicks four times. You must return the control panel to Bosch Security Systems, Inc. for exchange. If the Installer Code is unknown, a service fee is charged to unlock the control panel’s memory

When programmed to disable the default control panel setting, you cannot use the command [961#] to retrieve the programming data.

The use of this feature is not recommended.

Bosch Security Systems, Inc. 12/08 F01U089401-02

15

Page 15
Image 15
Bosch Appliances ICP-CC404 manual 2.5Disable Factory Defaults, Using this feature is not recommended