10.1.4 Basic Pager Reporting Format

ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats

Table 36: 4+2 Express Transmission Code Descriptions

Code

Description

SSSS

Subscriber ID Number

AAlarm

CH

Channel Number

0Zero

TTrouble

BBypass

EAC Fail Code 1st digit

AC

AC Fail Code 2nd digit

LLow Battery Code 1st digit

LB

Low Battery Code 2nd digit

OOpen

CClose

UUser Number

RAlarm Restore Code

TR

Trouble Restore Code

BR

Bypass Restore Code

ER

AC Fail Restore Code 1st digit

ACR

AC Fail Restore Code 2nd digit

LR

Low Battery Restore Code 1st digit

LBR

Low Battery Restore Code 2nd digit

DDuress Code 1st digit

D

0

Duress Code 2nd digit

PPanic Code 1st digit

PCH

Panic Code 2nd digit

TE

Test Code

10.1.4 Basic Pager Reporting Format

Although Basic Pager Format requires some interpretation of the numbers that appear on the display, it can differentiate between 1000 different control panels if a number of control panels report to the one pager.

To set up Receiver 1 for basic pager reporting:

1.Program the Basic Pager’s access telephone number in Locations 000 to 015 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 46).

2.Program the Subscriber ID Number in Locations 034 to 039 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 47).

3.Select Pager Handshake (Option 5) in

Location 032 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 47).

4.Program Basic Pager Format (Option 5) in Location 033 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 47).

To set up Receiver 2 for basic pager reporting:

1.Program the Basic Pager’s access telephone number in Locations 040 to 055 (refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 46).

2.Program the Subscriber ID Number in Locations 074 to 079 (refer to Section 11.5 Subscriber ID Number for Receiver 1 and Receiver 2 on page 47).

3.Select Pager Handshake (Option 5) in Location 072 (refer to Section 11.3 Handshake Tone for Receiver 1 and Receiver 2 on page 47).

4.Program Basic Pager Format (Option 5) in Location 073 (refer to Section 11.4 Transmission Format for Receiver 1 and Receiver 2 on page 47).

The example in Figure 6 shows:

Transmission from Subscriber ID Number 5678

Zone 2 in alarm

Zone 3 manually isolated

The system is armed

The Panic Zone is normal

The AC is connected

There is no fault condition.