ICP-CC404 Installation Guide 2.0 Programming

2.0 Programming

The control panel programming options are stored in

anon-volatile EPROM. This memory holds all configuration and user-specific data even after a total power loss.

Because the data retention time is up to ten years without power, no reprogramming is required after powering down the control panel.

You can change data as many times as necessary without any additional specialized equipment. The memory is organized in locations, each of which holds the data for a specific function.

15 is the maximum value that you can program into any location.

In general, the entire programming sequence consists of selecting the required location, and then entering or changing the current data. Repeat this procedure until you program all the required data. The factory default settings are selected for reporting to the monitoring station in Contact ID format.

The Installer Code provides access only to the Installer’s Programming Mode and does not allow you to arm and disarm the system. You cannot enter Installer’s Programming Mode when the system is armed, or at any time during siren run time.

You can program the ICP-CC404 Control Panel using any of these three devices:

Remote codepad

CC816 Alarm Link Upload/Download Software

2.1Programming with the Remote Codepad

To program the control panel using the remote codepad, the system must be disarmed with no alarm memory present.

To access Installer’s Programming Mode:

Enter the four-digit Installer Code (the factory default is 1234) and press [AWAY].

Two beeps sound and both the AWAY and the STAY indicators flash simultaneously to indicate that you entered Installer’s Programming Mode.

When you enter Installer’s Programming Mode, you are automatically positioned at Location 000, the first digit of the Primary Telephone Number for Receiver

1.The codepad indicators display the current data stored in this location.

Table 3:

 

Codepad Indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

Zone Indicators

 

 

 

Value

1

2

3

4

5

6

7

8

MAINS

0

1X

2 X

3

X

4 X

5

X

6 X

7

X

8 X

9

X

 

X

10

 

 

 

 

 

 

X

11

X

 

 

X

 

 

 

 

 

 

12

 

X

 

 

 

 

X

13

 

 

X

 

 

X

 

 

 

 

 

 

 

 

14

 

 

 

X

 

 

X

15

 

 

 

 

X

 

X

To move to a different programming location:

Enter the location number and press [AWAY].

For example, press [3 4][AWAY] to automatically step you to the beginning of the Subscriber ID Number for Receiver 1. The data stored in the new location appears.

To move to the next location:

Press [AWAY].

For example, if you are currently positioned at Location 034, press [AWAY] to step to Location 035.

To move to the previous location:

Press [STAY].

For example, if you are positioned at Location 035, press [STAY] to step back to Location 034.

To change data in the current location:

Enter the new value (0 to 15) and press [STAY].

The data is stored and you remain positioned at the same location. The codepad indicators show the new value (for example, if you enter [1 4] and press [STAY], the Zone 4 and MAINS indicators light).

To exit from the Installer’s Programming Mode:

Enter command [9 6 0] and press [AWAY].

Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state and is now ready for use.

Refer to Section 2.4 Installer’s Programming Commands on page 10 for more information about using Installer’s Programming Mode.

Bosch Security Systems, Inc. 12/08 F01U089401-02

9

Page 9
Image 9