Bosch Appliances ICP-CC404 manual 11.3Handshake Tone for Receiver 1 and Receiver

Models: ICP-CC404

1 98
Download 98 pages 40.39 Kb
Page 47
Image 47
11.3Handshake Tone for Receiver 1 and Receiver 2

ICP-CC404 Installation Guide 11.0 Dialer Information

When Receivers 1 or 2 is set up for domestic reporting, telephone numbers programmed into these locations are ignored. Refer to Section 6.1.2 Changing Domestic Phone Numbers on page 28 (using the Installer Code function) or Section 6.2.3 Changing Domestic Phone Numbers on page 33 (using the Master Code Function).

11.2Secondary Telephone Number for Receiver 1 and Receiver 2

Program the Secondary Telephone Number for Receiver 1 in Locations 016 to 031.

Program the Primary Telephone Number for Receiver 2 in Locations 056 to 071.

The default value for both telephone numbers is

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.

Refer to Section 11.1 Primary Telephone Number for Receiver 1 and Receiver 2 on page 46 for programming information.

When Receivers 1 or 2 are set up for domestic reporting, telephone numbers programmed into these locations are ignored. Refer to Section 6.1.2 Changing Domestic Phone Numbers on page 28 (using the Installer Code function) or Section 6.2.3 Changing Domestic Phone Numbers on page 33 (using the Master Code Function).

11.3Handshake Tone for Receiver 1 and Receiver 2

Program the Handshake Tone for Receiver 1 in Location 032.

Program the Handshake Tone for Receiver 2 in Location 072.

The default value for both Handshake Tones is 1.

These locations set the type of handshake tone required for the receivers before data transmissions to the monitoring station begin. The options are:

1 – HI LO Handshake

HI LO Handshake Tone is required to communicate in Contact ID Format or High Speed DTMF.

2 – 1400 Hz

1400 Hz Handshake Tone is required to communicate in Ademco Lo Speed Format or Domestic Dialing Format.

3 – 2300 Hz

Reserved.

4 – No Handshake

Setting these locations to No Handshake Tone is not recommended.

5 – Pager

Pager Handshake Tone is required to communicate in Basic Pager Format.

11.4Transmission Format for Receiver 1 and Receiver 2

Program the Transmission Format for Receiver 1 in Location 033.

Program the Transmission Format for Receiver 2 in Location 073.

The default value for both Transmission Formats is 1.

These locations select the data format used to send reports to the base station receiver. These locations also allow you to configure the control panel for domestic or basic pager formats. The options are:

1 – Contact ID

2 – 4 + 2 express

3 – FSK 300 baud Bell

4 – Domestic

5 – Basic Pager

7 – Reserved

The Basic Pager option supports only eight zones due to protocol limitations. If you use more than eight zones, this option is not recommended.

If you use the Zone 16, the 4+2 Express and FSK 300 Baud formats are not recommended because Zone 16 will be assigned as "0" and some receivers will not support this zone.

11.5Subscriber ID Number for Receiver 1 and Receiver 2

Program the Subscriber ID Number for Receiver 1 in Locations 034 to 039.

Program the Subscriber ID Number for Receiver 2 in Locations 074 to 079.

The default value for both Subscriber ID Numbers is 0 0 0 0 0 0.

The Subscriber ID Number is sent to identify the calling control panel.

For Basic Pager Format, Locations 034 to 036 (for Receiver 1) and Locations 074 to 076 (for Receiver 2) are ignored and the first digit of the Subscriber ID Number must start in Location 037 (Receiver 1) and Location 077 (Receiver 2).

Bosch Security Systems, Inc. 12/08 F01U089401-02

47

Page 47
Image 47
Bosch Appliances ICP-CC404 manual 11.3Handshake Tone for Receiver 1 and Receiver