ICP-CC404 Installation Guide 16.0 Programmable Outputs
2,13 Radio Control Output 1 – Not in AWAY Mode
This output operates when the [DOOR] button on the
2,14 Radio Control Output 2 – Not in AWAY Mode
This output operates when the [AUX] button on the
2,15 Communications Failure after Three Unsuccessful Calls
This output operates after the communication dialer makes three unsuccessful calls to the base station receiver. The output resets when all messages are sent (that is, when the message buffer is empty or when all possible attempts are made).
3,0 Communications Failure
This output operates after the communication dialer makes all possible attempts to reach the base station receiver. The output resets when the first
3,1 Dialer Disabled
This output operates when the Dialer reporting functions allowed Option 1 in Location 177 are not selected (refer to Section 12.1 Dialer Options 1 on page 50). The output resets when Option 1 is selected.
3,2 Dialer Active
This output operates when the communication dialer is online. The output resets when the communication dialer releases the telephone line.
3,3 Ring Detect
This output operates when the control panel detects an incoming call. The output resets when the ringing stops or when the call is answered.
3,5 Mimic Zone 1
3,6 Mimic Zone 2
3,7 Mimic Zone 3
3,8 Mimic Zone 4
3,9 Mimic Zone 5
3,10 Mimic Zone 6
3,11 Mimic Zone 7
3,12 Mimic Zone 8
These output types mimic the zone inputs. The output operates when the zone is unsealed and resets when the zone is sealed. They operate regardless of the selected zone type (for example, a zone programmed as Not Used can still operate a mimic output). This feature operates when the system is armed or disarmed.
4,5 Global Chime
This output operates when any Chime zones are activated. The output resets when the zone is resealed. Refer to Section 14.3.1 Zone Types on page 55 for more information.
4,6 Zone Not Sealed
This output operates when a Burglary Zone is unsealed. Chime zones do not operate this output.
4,7 Zone Not Sealed after Exit Time
This output operates at the end of Exit Time if a Burglary Zone is unsealed. The output resets when all zones are sealed or the system is disarmed. Chime zones do not operate this output.
4,9 AC Mains 60 Hz or 50 Hz
This output is activated when the AC mains supply frequency is 60 Hz. The output resets if the AC mains supply returns to 50 Hz.
16.3Output Polarity
There are fifteen different polarities. Each polarity is designated by a number that you program into the third location for the output.