ICP-CC404 Installation Guide 17.0 System Event Timers
You can program Entry Timer 1 from 0 to 255 sec in increments of 1 sec. Entry Timer 1 is the delay time used by the
17.3Entry Timer 2
Program Entry Timer 1 into Locations 400 (increments of 1 sec) and 401 (increments of 16 sec). The default value for Entry Timer 2 is 40 sec (8 2).
You can program Entry Timer 2 from 0 to 255 sec in increments of 1 sec. Entry Timer 2 is the delay time used by
17.4Exit Time
Program Exit Timer into Locations 402 (increments of 1 sec) and 403 (increments of 16 sec).
The default value for the Exit Timer is 60 sec (12 3).
You can program the Exit Timer from 0 to 255 sec in increments of 1 sec. When arming the system in AWAY Mode, the remote codepad beeps during Exit Time until the final 10 sec, when the codepad sounds one continuous beep to indicate the end of Exit Time is near.
The remote codepad always sounds one short beep at the end of Exit Time when arming in STAY Mode 1 or STAY Mode 2.
17.5Entry Guard Timer for STAY Mode
Program Entry Guard Timer for STAY Mode into Locations 404 (increments of 1 sec) and 405 (increments of 16 sec).
The default value for Entry Guard Timer for STAY Mode is 0.
Entry Guard Timer for STAY Mode is the delay time used for all zones except
17.6Delay Alarm Reporting Time
Program the Delay Alarm Reporting Time into Locations 406 (increments of 1 sec) and 407 (increments of 16 sec).
The default value for the Delay Alarm Reporting Time is 0.
These locations program the time in sec that a delayed report waits dormant in the dial buffer before it is sent to the receiving party. If a User Code holder resets the alarm within this time frame, the control panel clears the dialer buffer and does not report the alarm to the receiving party. Refer to Section 14.3.4 Zone Options 1 on page 57 to program zones for delay alarm reporting.
17.7Sensor Watch Time
Program Sensor Watch Time into Locations 408 (increments of days, tens digit) and 409 (increments of days, units digit).
The default value for the Sensor Watch Time is 0.
The time set in these two locations determines the number of days (0 to 99) a zone can remain sealed before registering as a fault. This feature is active only when the system is disarmed. If a zone programmed for Sensor Watch is not unsealed and reset during this time, the FAULT indicator lights. Refer to Section 4.13 Fault Descriptions on page 22 for more information on Sensor Watch Faults. Refer to Section 14.3.4 Zone Options 1 on page 57 for programming zones for Sensor Watch.
The Sensor Watch Time counter is active only when the control panel is disarmed. If the system is disarmed for 8 hours a day and the Sensor Watch Time is programmed for 1 day, a zone programmed for Sensor Watch registers a Sensor Watch Fault if it is not activated while disarmed within 3 days.
This feature is useful, for example, when someone places objects in the view of a motion detector, preventing the detector from picking up movement.
17.8Codepad Lockout Time
Program the Codepad Lockout Time into Location 410 (increments of 10 sec).
The default value for the Code Lockout Time is 0.
All codepads are locked out for the programmed time if an invalid code is entered more times than allowed by the code retry attempts programmed in Location 356 (refer to Section 15.19 System Status – Access Denied on page 63). If the Codepad Lockout Time is programmed as 0, codepad lockout does not occur.
17.9Siren Run Time
Program the Siren Run Time into Location 411 (increments of 1 minute).
The default value for the Siren Run Time is 5.
The Siren Run Time determines how long the horn speaker operates during an alarm. You can program the Siren Run Time from 0 to 15 min.
17.10 Siren Sound Rate
Program the Siren Sound Rate into Location 412. The default value for the Siren Sound Rate is 7.
Bosch Security Systems, Inc. 12/08 | 71 |