Table 33: Point ID Codes

ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats

Table 33: Point ID Codes

Point ID

Event Description

 

 

Zones 1 to 8

Burglary Zone

 

Medical Zone

 

Panic Zone

 

Hold-Up Zone

 

 

 

Tamper Zone

 

Burglary Zone

 

 

 

Fire

User Specific 1 to 16

Open/Close Report

 

 

040

AC MAINS Fail

031

Low Battery

 

 

User Specific 1 to 16

Codepad Duress

041

Codepad Panic

 

 

046

Codepad Fire

045

Codepad Medical

042

Code Retry Limit Exceeded

044

Test Report

047

Test Report

Zone Specific 1 to 8

Sensor Watch

Zone Specific 1 to 8

Trouble

Zone Specific 1 to 8

Bypass

 

 

00

AUX Power Supply Fail

 

 

Event Code 130

100

120

122

137

133

110

401

301

309

121

120

110

100

421

602

602

307

380

570

300

Explanation

Section

 

 

Burglary

14.3.1

24-Hour Medical

14.3.1

24-Hour Panic

14.3.1

24-Hour Hold-Up

14.3.1

 

 

24-Hour Tamper

14.3.1

24-Hour Burglary

14.3.1

 

 

24-Hour Fire

14.3.1

Opening – User #

15.7

Closing – User #

 

AC Power

15.15

Battery Test Failure

15.17

 

 

Duress Alarm

15.8

Panic Alarm

15.9

 

 

Fire Alarm

15.10

Medical Alarm

15.11

Access Denied

15.19

Test Report

15.21

Test Report

18.5

Sensor Self Test Failure

15.3

Sensor Trouble

15.2

Zone Bypass

15.1

 

 

System Trouble

15.13

 

 

10.1.2 Point ID Codes

Table 33 on page 43 shows the different Point ID Codes and Event Codes that are sent to the base station receiver when using Contact ID Reporting Format. All Event Codes are fixed. The control panel always sends the same code because there are no programming locations to change the codes.

10.1.3 4 + 2 Express Reporting Format

The 4 + 2 Express Format reports a Subscriber ID Number followed by an Expansion Code. The reporting Channel Number is sent directly after the Expansion Code.

Table 34: Example Reporting in 4 + 2 Express Format

 

 

 

Subscriber ID

Expansion

Channel

Number

Code

Number

 

 

 

SSSS

A

CH

Table 35: 4 + 2 Express Reporting Format

 

 

New Event

4 + 2 Report

Alarm

SSSS ACH

Trouble

SSSS TCH

Bypass

SSSS BCH

AC Fail

SSSS EAC

Low Battery

SSSS LLB

Opening Report

SSSS OU

 

 

Closing Report

SSSS CU

Test Report

SSSS TEO

Program Altered

SSSS P0

Duress

SSSS DD0

 

 

Event

4 + 2 Report

Alarm Restore

SSSS R CH

Trouble Restore

SSSS TR CH

Bypass Restore

SSSS BR CH

AC Fail Restore

SSSS ER ACR

Low Battery

SSSS L LB

Low Battery Restore

SSSS LBR

Bosch Security Systems, Inc. 12/08 F01U089401-02