ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats
Table 33: Point ID Codes
Point ID | Event Description |
|
|
Zones 1 to 8 | Burglary Zone |
| Medical Zone |
| Panic Zone |
| |
|
|
| Tamper Zone |
| Burglary Zone |
|
|
| Fire |
User Specific 1 to 16 | Open/Close Report |
|
|
040 | AC MAINS Fail |
031 | Low Battery |
|
|
User Specific 1 to 16 | Codepad Duress |
041 | Codepad Panic |
|
|
046 | Codepad Fire |
045 | Codepad Medical |
042 | Code Retry Limit Exceeded |
044 | Test Report |
047 | Test Report |
Zone Specific 1 to 8 | Sensor Watch |
Zone Specific 1 to 8 | Trouble |
Zone Specific 1 to 8 | Bypass |
|
|
00 | AUX Power Supply Fail |
|
|
Event Code 130
100
120
122
137
133
110
401
301
309
121
120
110
100
421
602
602
307
380
570
300
Explanation | Section |
|
|
Burglary | 14.3.1 |
14.3.1 | |
14.3.1 | |
14.3.1 | |
|
|
14.3.1 | |
14.3.1 | |
|
|
14.3.1 | |
Opening – User # | 15.7 |
Closing – User # |
|
AC Power | 15.15 |
Battery Test Failure | 15.17 |
|
|
Duress Alarm | 15.8 |
Panic Alarm | 15.9 |
|
|
Fire Alarm | 15.10 |
Medical Alarm | 15.11 |
Access Denied | 15.19 |
Test Report | 15.21 |
Test Report | 18.5 |
Sensor Self Test Failure | 15.3 |
Sensor Trouble | 15.2 |
Zone Bypass | 15.1 |
|
|
System Trouble | 15.13 |
|
|
10.1.2 Point ID Codes
Table 33 on page 43 shows the different Point ID Codes and Event Codes that are sent to the base station receiver when using Contact ID Reporting Format. All Event Codes are fixed. The control panel always sends the same code because there are no programming locations to change the codes.
10.1.3 4 + 2 Express Reporting Format
The 4 + 2 Express Format reports a Subscriber ID Number followed by an Expansion Code. The reporting Channel Number is sent directly after the Expansion Code.
Table 34: Example Reporting in 4 + 2 Express Format
|
|
|
Subscriber ID | Expansion | Channel |
Number | Code | Number |
|
|
|
SSSS | A | CH |
Table 35: 4 + 2 Express Reporting Format
|
|
New Event | 4 + 2 Report |
Alarm | SSSS ACH |
Trouble | SSSS TCH |
Bypass | SSSS BCH |
AC Fail | SSSS EAC |
Low Battery | SSSS LLB |
Opening Report | SSSS OU |
|
|
Closing Report | SSSS CU |
Test Report | SSSS TEO |
Program Altered | SSSS P0 |
Duress | SSSS DD0 |
|
|
Event | 4 + 2 Report |
Alarm Restore | SSSS R CH |
Trouble Restore | SSSS TR CH |
Bypass Restore | SSSS BR CH |
AC Fail Restore | SSSS ER ACR |
Low Battery | SSSS L LB |
Low Battery Restore | SSSS LBR |
Bosch Security Systems, Inc. 12/08 | 43 |