ICP-CC404 Installation Guide 6.0 System Functions

You can disable all zones selected to automatically isolate for STAY Mode 2 at any time.

To disable STAY Mode 2 zones:

Enter your Master Code and press [4][AWAY] [AWAY].

6.2.6Turning Outputs On/Off

If an output is programmed for remote operation, you can turn the remote output on or off using this Master Code function or remotely using the Alarm Link Software.

To use this Master Code function, you must program one or more of the outputs with these Output Event Types:

Output 1 = Output Event Type 2,8 (page 67) Output 2 = Output Event Type 2,9 (page 67) Output 3 = Output Event Type 2,10 (page 67)

To turn an output on from the remote codepad:

1.Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of the output (1 to 3) and press [AWAY].

Three beeps sound and the output turns on.

3.Repeat Step 2 to turn on another output.

4.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off.

Example

If Output 2 is programmed as 291000 in Locations 374 to 379, the Master Code holder can turn on this output by entering:

[2 5 8 0 5][AWAY][2][AWAY][AWAY]

To turn off an output from the remote codepad:

1.Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of the output (1 to 3) and press [STAY].

Two beeps sound and the output turns off.

3.Repeat Step 2 to turn off another output.

4.Press [AWAY] button to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off.

Example

If Output 2 is programmed as 291000 in Locations 374 to 379, the Master Code holder can turn off this output by entering:

[2 5 8 0 5][AWAY][2][STAY][AWAY]

6.2.7Setting the Date and Time

Use this function to change the date and time or if power was removed from the system.

If the date and time are not set, the date and time fault is shown only when the Auto Arming Time is programmed in Locations 414 to 417 (refer to Section

17.12Auto Arming Time on page 72), or when you enter Fault Analysis Mode by holding down [5].

To set the new date and time:

1.Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day, and MM minute of the day) and press [AWAY].

Use 24:00 hour format when programming the hour of the day.

Two beeps sound and the STAY and AWAY indicators turn off. If a long beep sounds, there was an error when you entered the date and time.

Example

To set the date and time for the 1st January 20064 at 10:30 PM, enter:

[2 5 8 0 6][AWAY][0 1 0 1 0 6 2 2 3 0][AWAY]

6.2.8Walk Test Mode

Walk Test Mode allows you to test detection devices to ensure they are functioning correctly. Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to Section 4.11 Isolating Zones on page 21 for more information.

To enter Walk Test Mode:

1.Enter your Master Code and press [7][AWAY]. Three beeps sound and the STAY and AWAY indicators flash. The codepad beeps once per sec when Walk Test Mode is active.

2.Unseal and seal the zones to be tested.

The codepad sounds one long beep and the horn speaker sounds one short beep each time a zone is sealed or unsealed.

3.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state.

6.2.9Event Memory Recall Mode

Event Memory Recall Mode allows you to play back the last forty system events. Event Memory Recall Mode shows all alarms and each arming or disarming of the system and helps with troubleshooting system faults. The events are shown using the codepad indicators.