ICP-CC404 Installation Guide 19.0 Optional Equipment

4 – Alarms Activate Sirens and Strobe Outputs in STAY Modes 1 and 2

Select this option if audible alarms are required when the system is armed in STAY Mode 1 or 2.

18.8Radio Input Options

Program the selected Radio Input Options in Location 431.

The default value is 0.

The options are:

1 – Radio Receiver (WE800E)

Select this option to use the WE800E 433 MHz RF Receiver for remote operations using radio remote hand-held transmitters.

2 – Latching Keyswitch Input

Selecting this option allows you to connect a latching keyswitch to the P5 terminals D and GND to remotely arm and disarm the system in AWAY Mode.

3 – Momentary Keyswitch Input

Selecting this option allows you to connect a momentary keyswitch to the P5 terminals D and GND to remotely arm and disarm the system in AWAY Mode.

19.0 Optional Equipment

Bosch Security Systems, Inc. manufactures a number of accessories that can be used with the ICP-CC404 Control Panel. These optional pieces of equipment enhance certain features making the system extremely flexible.

19.1RE012E/RE013E 2-Channel/

4-Channel Hand-Held Transmitters

433 MHz

These hand-held radio transmitters can be used with the RE005E 433 MHz RF Receiver to operate the system remotely. Both hand-held transmitters can remotely arm and disarm the system in AWAY Mode or STAY Mode 1 and can activate remote Panic Alarms. The four-channel hand-held transmitter can also operate outputs such as garage doors, swimming pool pumps, or outside lights.

19.2WE800E 433 MHz RF Receiver

This interface allows the use of up to eight radio User Codes (9 to 16). This is useful if you want the system to be radio controlled and you would like to give your customer total control using a radio hand-held remote transmitter.

Figure 10: WE800E Wireless ON/OFF Interface

1 – Direct link cable

2 – Receiver interface connection

3 – Wireless ON/OFF Interface

4 – Red

5 – Black

6 – Termination for phone line

7 – Socket for telecom lead connection

19.3RE005E Two-Channel Radio Interface

The two-channel radio interface allows customers to operate Control Panels remotely and to control two on-board relays. The interface can be used as a stand- alone receiver, independent of a Control Panel, used solely for remote control of external devices connected to the two on-board relays.

The interface’s operating frequency is 433 MHz with the ability to store up to 120 radio remote codes. Connect the interface to a Control Panel using a three-wire connection in parallel with the codepad and select Option 8 in Location 427 (refer to Section 18.4 System Options 4 on page 74).

19.4CC891 Programming Key

The programming key copies and stores all information programmed in your control panel. The programming key can hold all your common configuration data such as monitoring station telephone numbers and zone reporting channels.

19.5CC816 Alarm Link Software

This software can program the ICP-CC404 Control Panel by either the direct link or remote connect methods. This software can access all options and features and maintain history and service reports. Program options to use this feature in Location 180 (refer to Section 8.2 Alarm Link Options on page 40). Refer to Section 8.0 Alarm Link Software on page 39 for more information on using Alarm Link Software.

19.6 CP5 Eight Zone LED Codepad (CP508W)

This codepad operates with the range of control panels. It provides indications for up to eight zones.