ICP-CC404 Installation Guide 19.0 Optional Equipment
4 – Alarms Activate Sirens and Strobe Outputs in STAY Modes 1 and 2
Select this option if audible alarms are required when the system is armed in STAY Mode 1 or 2.
18.8Radio Input Options
Program the selected Radio Input Options in Location 431.
The default value is 0.
The options are:
1 – Radio Receiver (WE800E)
Select this option to use the WE800E 433 MHz RF Receiver for remote operations using radio remote
2 – Latching Keyswitch Input
Selecting this option allows you to connect a latching keyswitch to the P5 terminals D and GND to remotely arm and disarm the system in AWAY Mode.
3 – Momentary Keyswitch Input
Selecting this option allows you to connect a momentary keyswitch to the P5 terminals D and GND to remotely arm and disarm the system in AWAY Mode.
19.0 Optional Equipment
Bosch Security Systems, Inc. manufactures a number of accessories that can be used with the
19.1RE012E/RE013E
433 MHz
These
19.2WE800E 433 MHz RF Receiver
This interface allows the use of up to eight radio User Codes (9 to 16). This is useful if you want the system to be radio controlled and you would like to give your customer total control using a radio
Figure 10: WE800E Wireless ON/OFF Interface
1 – Direct link cable
2 – Receiver interface connection
3 – Wireless ON/OFF Interface
4 – Red
5 – Black
6 – Termination for phone line
7 – Socket for telecom lead connection
19.3RE005E Two-Channel Radio Interface
The
The interface’s operating frequency is 433 MHz with the ability to store up to 120 radio remote codes. Connect the interface to a Control Panel using a
19.4CC891 Programming Key
The programming key copies and stores all information programmed in your control panel. The programming key can hold all your common configuration data such as monitoring station telephone numbers and zone reporting channels.
19.5CC816 Alarm Link Software
This software can program the
19.6 CP5 Eight Zone LED Codepad (CP508W)
This codepad operates with the range of control panels. It provides indications for up to eight zones.
76 | Bosch Security Systems, Inc. 12/08 |