ICP-CC404 Installation Guide 9.0 Domestic Dialing
If a busy tone is not detected, the control panel assumes that the telephone was answered and sends its transmission. The transmission sequence consists of an identification beep, followed by a siren tone and a long pause. The transmission sequence is repeated until the control panel receives an acknowledgment tone during the pause. The control panel automatically hangs up after 2 min. If more than one control panel sends reports to the same telephone number, the identification beep allows the customer to identify the control panel that called. The identification beep is programmed in Location 039 of the Subscriber ID Number for Receiver 1 or Location 079 of the Subscriber ID Number for Receiver 2.
When set up for Domestic Dialing Format, the control panel attempts up to six calls per alarm event. This count includes any unsuccessful calls. The counter is reset if the zone is reactivated and the control panel attempts six additional calls. The control panel stops dialing after six attempts or three successful calls. The control panel also stops dialing if a valid User Code is entered at the remote codepad.
If both Receiver 1 and Receiver 2 are programmed for domestic dialing, the maximum number of calls per alarm event is twelve.
To acknowledge domestic dialing:
If the received call is not acknowledged during any of the transmission pauses by pressing the [*] button on
a
9.2Setting Up and Programming Domestic Reporting
Programming the control panel for domestic reporting is extremely simple when using the Installer’s Programming Command 965. Refer to Section 2.4.8 Command 965 – Set Up Domestic Dialing Format on page 13 for more information.
To set up the control panel for domestic dialing:
1.Enter the Installer Code and press [AWAY] to enter Installer’s Programming Mode.
Two beeps sound and the STAY and AWAY indicators flash.
2.Enter [9 6 5] and press [AWAY].
Two beeps sound. The control panel is now set up for Domestic Dialing Format.
3.Enter [9 6 0] and press [AWAY] to exit from the Installer’s Programming Mode.
Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state.
4.To program your telephone numbers, enter the Installer Code and press [2][AWAY].
Three beeps sound and the STAY and AWAY indicators flash.
If there are telephone numbers already programmed, they appear one digit at a time using the codepad indicators.
If there are no programmed telephone numbers, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the last phone number lights.
5.Enter the digits for telephone number 1, one digit at a time (refer to Table 31).
As you enter each digit, the corresponding codepad indicator lights.
Table 31: Domestic Dialing Digits
|
|
|
|
Digit | Number to | Digit | Number to |
Required | Program | Required | Program |
|
|
|
|
0 | 0 | 8 | 8 |
1 | 1 | 9 | 9 |
2 | 2 | 10 | refer to 0 |
3 | 3 | * | * 1 |
4 | 4 | # | * 2 |
5 | 5 | 4 sec pause | * 3 |
|
|
|
|
6 | 6 | break | * 4 |
7 | 7 | 15 | * 5 |
6.After you enter all the digits of the first telephone number, press [STAY][4] to insert a break between the first telephone number and the second telephone number.
7.Repeat Step 6 for each additional phone number.
8.After the last digit of the last telephone number, press [AWAY] to exit from this mode.
Example
To program two separate telephone numbers (9672
1777 and 9672 1233), enter the following sequence:
[1 2 3 4 2][AWAY][9 6 7 2 1 7 7 7][STAY]
[4 9 6 7 2 1 2 3 3][[AWAY]
You can cancel domestic dialing at any time (for example, you are moving house and do not want the system to continue calling your work place or mobile phone).
To disable domestic dialing:
Enter the Installer Code and press [2][AWAY][STAY][4][AWAY].
Bosch Security Systems, Inc. 12/08 | 41 |