ICP-CC404 Installation Guide 6.0 System Functions

To enter Satellite Siren Service Mode:

Enter the Installer Code and press [5][AWAY].

Three beeps sound.

6.1.6Turning Telephone Monitor Mode On and Off

Telephone Monitor Mode allows you to use the remote codepad for visual representation of data transmissions between the control panel and the base station receiver. The dialing sequence is also shown in this mode.

The codepad beeps once every 2 sec when Telephone Monitor Mode is active, whether the system is in Installer’s Programming Mode or normal operating mode. The first five indicators show the progressive steps during a transmission to the base station receiver.

Table 24: Telephone Monitor Mode Indications

 

 

Zone LED

Dialing Event

1

Telephone line seized

2

Dialing phone number

 

 

3

Handshake received

4

Data being transmitted

 

 

5

Kiss-off received

None

Telephone line released

To turn Telephone Monitor Mode on: Enter the Installer Code and press [6][AWAY]. Three beeps sound.

To turn Telephone Monitor Mode off: Enter the Installer Code and press [6][AWAY]. Two beeps sound.

You must exit from Telephone Monitor

Mode to resume normal operations.

6.1.7Walk Test Mode

Walk Test Mode allows you to test detection devices to ensure they are functioning correctly. Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to Section 4.11 Isolating Zones on page 21 for more information.

To enter Walk Test Mode:

1.Enter the Installer Code and press [7][AWAY]. Three beeps sound and the STAY and AWAY indicators flash. The codepad beeps once per sec when Walk Test Mode is active.

2.Unseal and seal the zones to be tested.

The codepad sounds one long beep and the horn speaker sounds one short beep each time a zone is sealed or unsealed.

3.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state.

6.1.8Event Memory Recall Mode

This function allows you to play back the last 40 system events that occurred. Event Memory Recall Mode reports all alarms and each arming or disarming of the system and helps with troubleshooting system faults. The events are shown using the codepad indicators.

To enter Event Memory Recall Mode:

Enter the Installer Code and press [8][AWAY]. Three beeps sound. The events are played back by the codepad indicators in reverse chronological order.

Example

If the events occurred in the following order:

1.System armed in AWAY Mode

2.Alarm in Zone 3

3.Alarm in Zone 4

4.System disarmed

The alarm memory plays back in this order:

1.All indicators off except MAINS (System disarmed)

2.Zone 4 and AWAY indicators light (Alarm in Zone 4)

3.Zone 3 and AWAY indicators light (Alarm in Zone 3)

4.AWAY indicator lights (System armed in AWAY Mode)

Each event is indicated by a beep and a lit indicator. Resetting a disarmed 24-Hour Alarm is indicated by a beep only.

After the last event, three beeps sound to indicate the end of playback. You can stop the replay at any time by pressing [AWAY].

If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.

If power is removed from the control panel, the memory of all events is saved.

6.2Master Code Functions

Master Code Functions allow users with the appropriate priority level to perform certain supervisory level functions. You can use these functions only when the system is disarmed.