ICP-CC404 Installation Guide 6.0 System Functions

If there is no Telco disarming sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is shown.

3.Press [STAY][2 6 1][STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the Telco disarming sequence at any time.

To disable the Telco disarming sequence:

Enter your Master Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

To program the Telco arming sequence – easy call forward (immediate on):

1.Enter your Master Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [1][AWAY] button to change the Telco arming sequence. Three beeps sound.

If a call forwarding sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 30 for the indicators and their meanings.

If there is no call forward sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the call forward sequence is displayed.

3.Press [STAY][1 2 1] and enter the phone number to which you want calls from the control panel diverted.

4.Press [STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

Example

If you want to automatically divert all incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter:

[2 5 8 0 3][AWAY][1][AWAY][STAY] [1 2 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]

You can suspend the Telco arming sequence at any time.

To disable the Telco arming sequence:

Enter your Master Code and press [3][AWAY][1] [AWAY][STAY][4][AWAY].

To program the Telco disarming sequence – easy call forward (immediate off):

1.Enter your Master Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [2][AWAY] to change the Telco disarming sequence.

Three beeps sound.

If a Telco disarming sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 30 on page 34 for the indicators and their meanings.

If there is no Telco disarming sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is shown.

3.Press [STAY][2 2 1][STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the Telco disarming sequence at any time.

To disable the Telco disarming sequence:

Enter your Master Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

6.2.5Setting STAY Mode 2 Zones

This function allows the Master Code holder to select the zones that are automatically isolated when the system is armed in STAY Mode 2.

To arm the system in STAY Mode 2, press and hold

[0]until two beeps sound. Refer to Section 6.3.3 on page 37 or Section 4.5 Arming the System in STAY Mode 2 on page 20 for more information.

To set STAY Mode 2 zones:

1.Enter your Master Code and press [4][AWAY]. Three beeps sound and the STAY indicator flashes.

2.Enter the number of the zone you want to automatically isolate and press [STAY]. The corresponding zone indicator flashes.

3.Repeat Step 2 to select each zone.

As you select each zone to isolate, the corresponding zone indicator flashes. If you make a mistake, enter the incorrect zone number and press [STAY]. This zone is no longer selected to be isolated and the zone indicator is extinguished.

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

The indicators for the zones you selected and the STAY indicator turn off.

Example

If you want to select zones 2, 5, and 6, enter:

[2 5 8 0 4][AWAY][2][STAY][5][STAY][6][STAY] [AWAY]