6.1.4Setting STAY Mode 2 Zones

ICP-CC404 Installation Guide 6.0 System Functions

To disable the Telco disarming sequence:

Enter the Installer Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

To program the Telco arming sequence – easy call forward (immediate on):

1.Enter the Installer Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [1][AWAY] button to change the Telco arming sequence. Three beeps sound.

If a call forwarding sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 23 on page 29 for the indicators and their meanings.

If there is no call forward sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the call forward sequence is shown.

3.Press [STAY][1 2 1] and enter the phone number to which you want calls from the control panel diverted.

4.Press [STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

Example

If you want to automatically divert all incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter:

[1 2 3 4 3][AWAY][1][AWAY][STAY] [1 2 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]

You can suspend the Telco arming sequence at any time.

To disable the Telco arming sequence:

Enter the Installer Code and press [3][AWAY][1] [AWAY][STAY][4][AWAY].

To program the Telco disarming sequence – easy call forward (immediate off):

1.Enter the Installer Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [2][AWAY] to change the Telco disarming sequence.

Three beeps sound.

If a Telco disarming sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 23 for the indicators and their meanings.

If there is no Telco disarming sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence appears.

3.Press [STAY][2 2 1][STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the Telco disarming sequence at any time.

To disable the Telco disarming sequence:

Enter the Installer Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

6.1.4Setting STAY Mode 2 Zones

This function allows the installer to select the zones that are automatically isolated when the system is armed in STAY Mode 2.

To arm the system in STAY Mode 2, press and hold [0] until two beeps sound.

Refer to Section 6.3.3 on page 37 or Section 4.5 Arming the System in STAY Mode 2 on page 17 for more information.

To set STAY Mode 2 zones:

1.Enter the Installer Code and press [4][AWAY]. Three beeps sound and the STAY indicator flashes.

2.Enter the number of the zone you want to automatically isolate and press [STAY]. The corresponding zone indicator flashes.

3.Repeat Step 2 for each zone you want to select.

As you select each zone to isolate, the corresponding zone indicator flashes. If you make a mistake, enter the incorrect zone number and press [STAY]. This zone is no longer selected to isolate and the zone indicator turns off.

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

The indicators for the zones you selected and the STAY indicator turn off.

Example

If you want to select zones 2, 5, and 6, enter:

[1 2 3 4 4][AWAY][2][STAY][5][STAY][6][STAY] [AWAY]

You can disable all zones selected to automatically isolate for STAY Mode 2 at any time.

To disable STAY Mode 2 zones:

Enter the Installer Code and press [4][AWAY] [AWAY].

6.1.5Satellite Siren Service Mode

If the SS914 Satellite Siren (EDMSAT) is connected to Output 1, this function allows you to perform service work on the system without activating the satellite siren. The satellite siren returns to its normal working state the next time the system is armed.