Bosch Appliances ICP-CC404 Programming, Command 965 Defaults, Example Auto Step Mode Enabled

Models: ICP-CC404

1 98
Download 98 pages 40.39 Kb
Page 14
Image 14
Programming

 

ICP-CC404 Installation Guide

2.0

Programming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6:

Command 965 Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

Description

 

Default Value

Setting

 

 

 

 

 

 

 

 

 

032

 

Handshake Tone for Receiver 1

1

(Handshake Tone)

 

 

033

 

Transmission Format

 

4

(Domestic)

 

 

 

 

 

 

 

 

 

 

034 to 039

 

Subscriber ID Number

 

0, 0, 0, 0, 0, 1

(1 Beep)

 

 

332

 

Zone Status Reporting Options

2

(Receiver 2 only)

 

 

333 and 334

 

Open/Close Reports

 

11, 12

(Open/Close Reports)

 

 

335

 

Open/Close Reporting Options

2

(Receiver 2 only)

 

 

 

 

 

 

 

 

 

356 to 358

 

System Status – Access Denied

6, 7, 12

(Access Denied)

 

 

359

 

System Status Reporting Options

2

(Receiver 2 only)

 

 

360 to 366

 

Test Report Time

 

0, 0, 0, 0, 7, 1, 0

(Test Reports)

 

 

367

 

Test Reporting Dialer Options

1

(Receiver 1 only)

 

Example (Auto Step Mode Enabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when Auto Step Mode is enabled:

1.Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

2.To program the number, press:

[10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]

Example (Auto Step Mode Disabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when Auto Step Mode is disabled:

1.Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

2.To program the number, press:

[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 10 * # 5 * # 5 * # 0 *]

2.4.10Command 999 – Display the Panel Type or Software Version Number

When using the remote codepad, this command shows the version of the control panel. Because different control panels use the same printed circuit board (PCB), it is difficult to determine the control panel the PCB is set to.

To show the control panel type or software version number:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the remote codepad shows the data programmed in Location 000.

If you are using the remote codepad, the STAY and AWAY indicators flash to indicate you entered Installer’s Programming Mode.

2.Enter [9 9 9 #]. Two beeps sound.

If you are using the remote codepad, the codepad displays a zone indicator corresponding to the control panel type. Refer to Table 7 for more information.

Table 7: Control Panel Type

Indicator

Control Panel Type

4ICP-CC404

8ICP-CC408 ICP-CC488

3.Press [#] to exit from this command and return to the Installer’s Programming Mode.

4.Enter [9 6 0 #] to exit from the Installer's Programming Mode.

Two sound and the system returns to the disarmed state.

If you are using the remote codepad, the STAY and AWAY indicators turn off to indicate the system is disarmed.

14

Bosch Security Systems, Inc. 12/08 F01U089401-02

Page 14
Image 14
Bosch Appliances ICP-CC404 Programming, Command 965 Defaults, Example Auto Step Mode Enabled, Control Panel Type, Table