Bosch Security Systems, Inc. 12/08 F01U089401-02

 

ICP-CC404 Installation Guide

22.0

Programming Sheets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

 

 

 

 

Options/Notes

 

 

 

 

 

Default/

 

 

Function

 

 

 

 

 

 

 

 

Programming Entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

267 to 322

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Definitions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 0 0 1 14 1 1

 

 

 

 

 

 

12 0 0 1 12 1 1

 

 

Zone #01

 

 

(Delay 1)

 

Zone #05

(Fixed 24-hr burglary)

 

(267 to 273)

 

 

 

 

 

 

 

 

 

(295 to 301)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 0 0 1 14 1 1

 

 

 

 

 

 

12 0 0 1 12 1 1

 

 

Zone #02

 

(Handover)

 

Zone #06

(Fixed 24-hr burglary)

 

(274 to 280)

 

 

 

 

 

 

 

 

 

(302 to 308)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 0 0 1 14 1 1

 

 

 

 

 

 

13 0 0 1 12 1 1

 

 

Zone #03

 

(Handover)

 

Zone #07

 

(Fixed 24-hr fire)

 

(281 to 287)

 

 

 

 

 

 

 

 

 

(309 to 315)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 0 0 1 14 1 1

 

 

 

 

 

 

9 0 0 1 12 1 1

 

 

Zone #04

 

 

(Instant)

 

Zone #08

 

 

(Fixed Tamper)

 

(288 to 294)

 

 

 

 

 

 

 

 

 

(316 to 322)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The first location (from the left) of the zone definition is the Zone Type. The options are:

 

0

Instant

4

Reserved

8

24-hour hold-up

12

24-hour burglary

1

Handover

5

Reserved

9

24-hour tamper

13

24-hour fire

2

Delay 1

6

24-hour medical

10

Reserved

14

Chime

3

Delay 2

7

24-hour panic

11

Keyswitch

15

Not used

The second location of the zone definition is the Zone Pulse Count. Use the pulse count to program the number of pulses (0 to 15) that must register within the pulse count time to activate an alarm.

The third location (from the left) of the zone definition is the Zone Pulse Count Time. The options are:

 

20 ms Loop Response Time:

 

150 ms Loop Response Time:

0

0.5 sec

4

4 sec

8

20 sec

12

60 sec

1

1 sec

5

5 sec

9

30 sec

13

90 sec

2

2 sec

6

10 sec

10

40 sec

14

120 sec

3

3 sec

7

15 sec

11

50 sec

15

200 sec

The fourth location of the zone definition is the Zone Options 1 parameter. The options are:

1

Lockout siren/dialer

4

Silent alarm

2

Delay Alarm Report

8

Sensor watch

The fifth location of the zone definition is the Zone Options 2 parameter. The options are:

1

Isolated in STAY Mode 1

4

Forced arming allowed

2

Zone isolation allowed

8

Zone Restore Report allowed

The sixth location of the zone definition is the Report Code. The options are:

0Do not send Zone Alarm Reports

1 Send Zone Alarm Reports

The seventh location of the zone definition is the Zone Dialer Options parameter. The options are:

0

No Zone Reports allowed

4

Report to both Receiver 1 and Receiver 2

1

Report to Receiver 1

8

Report to Receiver 2 only if Receiver 1

2

Report to Receiver 2

 

fails

The keyswitch zone options replace Zone Options 1 for zones programmed to operate as keyswitch

zones (Zone Type = 11). The options are:

 

 

0

Latching arm and disarm in AWAY Mode

8

Momentary arm and disarm in AWAY

1

Latching arm in AWAY Mode

 

Mode

2

Latching disarm from AWAY Mode or

9

Momentary arm In AWAY Mode

 

STAY Mode

10

Momentary disarm from AWAY Mode or

4

Latching arm and disarm in STAY Mode

 

STAY Mode

5

Latching arm in STAY Mode

12

Momentary arm and disarm in STAY Mode

6

Latching disarm from STAY Mode

13

Momentary arm in STAY Mode

 

 

14

Momentary disarm from STAY Mode

88

Page 88
Image 88