ICP-CC404 Installation Guide 11.0 Dialer Information

To turn call forward (no answer) off, enter:

[# 6 1 #]

Example

To disable call forward (no answer) after disarming the system from AWAY Mode, program:

12 6 1 12 0 0 0 0 0 0 0 0 0 0 0 0

11.9Call Back Telephone Number

Program the Call Back Telephone Number in Locations 159 to 174.

The default value for the Call Back Telephone Number is 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.

This parameter stores the telephone number to call when Upload/Download is requested or the user holds down [6] to initiate a modem call from the control panel to establish a communications link with the remote computer. The computer must be running the CC816 Alarm Link Software and must be set to Waiting for an Incoming Call.

The Call Back Telephone Number is also required if Remote Connect with Callback Verification is required (refer to Section 8.1.3 on page 39).

Refer to Section 8.0 Alarm Link Software on page 39 for more information.

11.10 Ring Count

Program the Ring Count in Location 175.

The default value for the Ring Count is 8.

Programming this location to a value from 1 to 13 sets that number of rings before the control panel answers an incoming call. Set this count to an acceptable level, noting that one ring is “Ring, Ring – Ring, Ring” and that a Ring Count of 10 represents approximately 60 sec. This location has an effect only if Remote Arming, Remote Upload/Download using Alarm Link, or both are enabled.

Programming this location to 0 prevents the control panel from answering incoming calls regardless of any other programmed options.

Answering Machine Bypass

Answering Machine Bypass allows connecting with the control panel for Remote Arming or Upload/Download when an answering machine or facsimile machine is on the same telephone line. There are two different Answering Machine Bypass methods. Program a 14 to use the secondary method only when there is a large amount of traffic on the line (at a home office, for example). This method reduces the chance of the control panel incorrectly answering an incoming call.

Programming the Ring Count to 15 enables Answering Machine Bypass in the primary mode. When calling the control panel, allow the telephone to ring no more than four rings then hang up. If you call again within 45 sec, the control panel answers the call on the first ring and the connection is established. This prevents the answering machine or facsimile machine from answering the call. To enable Answering Machine Bypass only when the system is armed, select Option 2 in Location 177 (refer to Section 12.1 Dialer Options 1 on page 50).

Program the Ring Count to 14 to enable Answering Machine Bypass in the secondary mode. In this case, call the control panel and allow the phone to ring no more than two rings and hang up. Wait at least 8 sec and call the control panel again. The control panel answers on the first ring. If you do not wait the 8 sec, the control panel does not answer the call. To enable Answering Machine Bypass only when the system is armed, select Option 2 in Location 177 (refer to Section 12.1 Dialer Options 1 on page 50).

Set the Ring Count for the answering or facsimile machine to a value greater than two rings. Four to six rings is preferred.

Program a 0 into this location to disable the control panel from answering an incoming call.

11.11 Telephone Line Fault Options

Program the selected Telephone Line Fault Options in Location 176.

The default value is 0.

This location has three options. You can select any combination of these options by programming a single value. Calculate this value by adding the option bit numbers together. Refer to Section 2.3 Programming Option Bits on page 10 for more information.

The control panel monitors the telephone line. If the telephone line is cut or disconnected for longer than 40 sec, the control panel lights the FAULT indicator on the codepad. The FAULT indicator is extinguished after the telephone line is restored for longer than 40 sec.

Option 2 and 4 do not operate unless you also enable Option 1.

Bosch Security Systems, Inc. 12/08 F01U089401-02

49