ICP-CC404 Installation Guide 3.0 Codepad Indicators
3.0Codepad Indicators
3.1ICP-CP508W Eight Zone LED
Codepad
Figure 1: ICP-CP508W Eight Zone LED Codepad
The codepad is the communications interface between you and the alarm system. The codepad allows you to issue commands and offers visual and audible indications to guide you through general operation.
The codepad incorporates a number of indicators: eight zone indicators show the condition of each zone and four other indicators show general status. These indicators are described in Table 8 through Table 13 on page 17.
Zone Indicators
Table 8: Zone Indicators
|
|
Indicator | Definition |
On | The zone is unsealed |
Off | The zone is sealed |
Flashing fast | The zone is in alarm |
(0.25 sec on/0.25 sec off) |
|
Flashing slow | The zone is manually |
(1 sec on/1 sec off) | isolated |
STAY Indicator
The STAY indicator lights when the system is armed in STAY Mode 1 or STAY Mode 2. The STAY indicator flashes with the AWAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.
For more information, refer to:
•Section 4.3 on page 19 to arm the system in STAY Mode 1.
•Section 14.3.4 on page 57 to set zones to automatically isolate in STAY Mode 1.
•Section 4.5 on page 20 to arm the system in STAY Mode 2.
•Section 6.1.4 on page 30 to use the Installer Code to set zones to automatically isolate in STAY Mode 2.
•Section 6.2.5 on page 35 to use the Master Code to set zones to automatically isolate in STAY Mode 2.
Table 9: STAY Indicator
|
|
Indicator | Definition |
On | The system is armed in STAY Mode 1 or |
| STAY Mode 2 |
Off | The system is not armed in STAY Mode 1 or |
| STAY Mode 2 |
|
|
Flashing | Zone Isolating Mode or setting STAY Mode 2 |
| zones |
AWAY Indicator
The AWAY indicator lights when the system is armed in AWAY Mode. The AWAY indicator flashes with the STAY indicator when you are in Installer’s Programming Mode or you are using a Master Code function.
Refer to Section 4.1 Arming the System in AWAY Mode on page 18 for more information.
Table 10: AWAY Indicator
|
|
Indicator | Definition |
On | The system is armed in AWAY Mode |
Off | The system is not armed in AWAY Mode |
MAINS Indicator
The MAINS indicator shows whether the system’s AC MAINS supply is normal or failed.
When programming in Installer’s Programming Mode or using a Master Code function, the MAINS indicator lights to indicate a location value from 10 to 15. The MAINS indicator represents the 10 digit, which is added to the value of the lit zone indicator (for example, if the value programmed in a location is 12, the MAINS and Zone 2 indicators light).
Table 11: MAINS Indicator
|
|
Indicator | Definition |
On | The AC MAINS power is normal |
Flashing | The AC MAINS supply failed |
FAULT Indicator
The FAULT indicator lights when the system detects a system fault. Refer to Section 4.12 Fault Analysis Mode on page 22 for more information on system faults.
Each time a new system fault is detected (the FAULT indicator flashes), the codepad beeps once per minute.
Press [AWAY] to stop the beeping and to acknowledge the fault.
16 | Bosch Security Systems, Inc. 12/08 |