ICP-CC404 Installation Guide 22.0 Programming Sheets

Location

 

 

 

Options/Notes

 

 

 

 

 

 

 

Default/

 

Function

 

 

 

 

 

 

Programming Entry

 

 

 

 

 

 

 

 

 

368 to 397

The fifth and sixth locations of the output definition provide the time base multiplier. Enter a value between

Outputs

01 and 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(continued)

One Shot Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you program the output polarity as one shot, the time base is multiplied by the time base multiplier.

 

For example, if the time base = 2 and the multiplier = 05, the output operates for 5 sec.

 

 

 

 

 

 

 

 

Pulsing Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you program the output polarity as pulsing, the time base becomes the ON time and the multiplier

 

 

 

becomes the OFF time. The OFF time is the time base, which is multiplied by the multiplier. For example,

 

 

 

if you want the output to pulse 1 sec ON and 5 sec OFF, you would program time base as 2 and the

 

 

 

multiplier as 5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

398 to 399

 

 

 

Location 398: increments of 1 sec (0 to 15 sec)

 

 

 

4

1

Entry Time 1

 

 

 

Location 399: increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400 to 401

 

 

 

Location 400: increments of 1 sec (0 to 15 sec)

 

 

 

8

2

Entry Time 2

 

 

 

Location 401: increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

402 to 403

 

 

 

Location 402: increments of 1 sec (0 to 15 sec)

 

 

 

12

3

Exit Time (AWAY/STAY Modes)

 

 

Location 403: increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

404 to 405

 

 

 

Location 404: increments of 1 sec (0 to 15 sec)

 

 

 

0

0

Entry Guard Time for STAY Mode

 

 

Location 405: increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

406 to 407

 

 

 

Location 406: increments of 1 sec (0 to 15 sec)

 

 

 

0

0

Delay Alarm Report Time

 

 

Location 407: increments of 16 sec (0 to 240 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

408 to 409

 

 

 

Location 408: increments of days (tens digit)

 

 

 

0

0

Sensor Watch Time

 

 

Location 409: increments of days (units digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

410

 

0

No lockout

 

 

 

 

 

 

 

0

Codepad Lockout Time

 

1 to 15 Increments of 10 sec (10 sec to 150 sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

411

 

0

No siren time

 

 

 

 

 

 

 

5

Siren Run Time

 

 

1 to 15 Increments of 1 min (1 min to 15 min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

412

 

 

0 to 15 (slowest to fastest frequency)

 

 

 

 

 

 

 

7

Siren Sound Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

413

 

0

No pre-alert time

 

 

 

 

 

 

 

1

Auto Arming Pre-Alert Time

 

1 to 15 Increments of 5 min (5 min to 75 min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

414 to 417

 

 

 

Location 414: Hour of day (tens digit)

 

 

0

0

0

0

Auto Arming Time

 

 

Location 415: Hour of day (units digit)

 

 

 

 

 

 

 

 

 

Refer to page 72

 

 

Location 416: Minute of day (tens digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 417: Minute of day (units digit)

 

 

 

 

 

 

 

 

 

418 to 421

 

 

 

Location 418: Hour of day (tens digit)

 

 

0

0

0

0

Auto Disarming Time

 

 

Location 419: Hour of day (units digit)

 

 

 

 

 

 

 

 

 

Refer to page 72

 

 

Location 420: Minute of day (tens digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 421: Minute of day (units digit)

 

 

 

 

 

 

 

 

 

422

 

 

0 to 15 Increments of 500 ms (500 ms to 8 sec)

 

 

 

 

 

 

 

3

Kiss-Off Wait Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

423

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

424

 

 

1 Bosch smart lockout allowed

 

 

 

 

 

 

 

1

System Options 1

 

2 Horn speaker monitor

 

 

 

 

 

 

 

 

 

Refer to page 73

 

4 Strobe indication for radio arm/disarm

 

 

 

 

 

 

 

 

 

 

 

 

8 Horn speaker beeps for radio arm/disarm

 

 

 

 

 

 

 

 

 