21.0 Specifications

ICP-CC404 Installation Guide 21.0 Specifications

21.0 Specifications

Table 66: Specifications

 

 

Temperature Range

0oC to +45 oC

 

(+32 oF to +113 oF)

Humidity

10% to 95%

Power Source

TF008 Plug Pack –

 

240 VAC/18 VAC @ 1.3 A

Standby Current

65 mA

Current Draw In Alarm

115 mA

 

 

Current Draw In Alarm

105 mA

with Codepad

 

Backup Battery

6 Ah/12 VDC Rechargeable

 

sealed lead acid battery

Dimensions (case,

30.6 cm x 26.2 cm x 8.4 cm

packed in carton)

(12.1 in. x 10.3 in. x 3.3 in.)

Weight

2.5 kg (5.5 lb)

Supplier Code

N771

New Zealand Telepermit

PTC 211/98/085

The Austel permit issued for this product is subject to the following conditions: The ICP-CC404 Control Panel can only be powered by a Bosch Security Systems, Inc. TF008 Plug Pack (Approval Number Q92128).

21.1Warranty Statement

Bosch Security Systems, Inc. warrants this product to be free from defects in material and workmanship for a period of three years from the date of manufacture as indicated by the date stamp or the serial number on the product.

Defective units returned by the purchaser at their own expense during this period will be repaired or replaced at the option of the manufacturer. The repair or replacement is free of charge provided that the defects were not incurred during shipping or handling, or the damage was not due to causes beyond the control of Bosch Security Systems, Inc., such as lightning, excessive voltage, mechanical shock, or damage arising out of abuse, alteration, or improper application of the equipment.

21.2Advice to Users

The Austel permit issued for this product is subject to this condition:

The ICP-CC404 Control Panel can only be powered by a TF008 Plug Pack (Approval Number Q92128).

21.3New Zealand Telepermit Notes

The grant of a telepermit for a device does not indicate telecom acceptance of responsibility for the correct operation of the device under all operating conditions.

This equipment shall not be used in any manner that could constitute a nuisance to other telecom customers.

Disconnect this equipment immediately if it becomes physically damaged and arrange for its disposal or repair.

The transmit level from this device is set at a fixed level, so there might be circumstances where the performance is less than optimal.

Before reporting such occurrences as faults, please check the line with a standard telepermitted telephone and do not report a fault if the telephone performance is satisfactory.

This device is equipped with pulse dialing while the telecom standard is DTMF tone dialing. There is no guarantee that telecom lines will always continue to support pulse dialing.

Use of dialing, when this equipment is connected to the same line as other equipment, can give rise to bell tinkle or noise and can also cause a false answer condition. If problems such as this occur, the user should not contact the Telecom Faults Service.

This equipment is set up to carry out test calls at pre-determined times. These test calls interrupt other calls that might be set up on the line at the same time. Discuss the timing set for these test calls with the installer.

The timing set for test calls from this equipment may be subject to drift. If this proves to be inconvenient and your calls are interrupted, discuss the problem of timing with the equipment installer. Do not report the matter as a fault to Telecom Faults Service.

This equipment shall not be set up to make automatic calls to the Telecom 111 Emergency Service.

This equipment should not be used under any circumstances that may constitute a nuisance to other Telecom customers.

In the event of any problem with this device, disconnect the system battery, AC mains supply, and the telephone line. The user must arrange with the supplier of the device for the necessary repairs.

If the matter is reported to telecom as a wiring fault and the fault is proven to be due to this product, a call-out charge is incurred.

84