20.2Glossary Of Terms
Table 65: Glossary
| Term | Description |
|
| A monitored input where tamper switches and emergency switches can be connected. |
| |
|
| If one of these switches is violated at any time (whether the system is armed or |
|
|
| disarmed), an alarm is reported. |
|
| alarm condition | The status when an alarm system is armed and one of the detection devices is violated. |
|
|
| A |
|
|
| armed or disarmed. |
|
| answering machine | A condition that enables connection with the control panel for remote arming or remote |
|
| bypass | programming operations when there is an answering machine or facsimile machine on |
|
|
| the same telephone line. |
|
| Armed (System ON) | A status in which the system is ready to accept alarms. |
|
| automatic arming | Programming that allows the system to arm automatically at the same time each day in |
|
|
| AWAY Mode or STAY Mode 1. |
|
| automatic disarming | Programming that allows the system to disarm automatically at the same time each day |
|
|
| in AWAY Mode or STAY Mode 1. |
|
| AWAY or # | A codepad button used to execute any given command. |
|
| AWAY Mode | The mode used to arm your system when you leave your premises. |
|
| codepad | A device that allows you to perform all functions such as arming, disarming, and |
|
|
| programming of your alarm system. |
|
| day alarm | Programming that allows a combination of zones to be monitored while the system is |
|
|
| disarmed. |
|
| detector | A unit installed as a satellite component in a security system designed to detect an |
|
|
| intruder within a protected area. Some common forms of detection devices are passive |
|
|
| infrared, smoke, photo electric beams, reed switches, and vibration sensors. |
|
| dialer | An electronic device that uses tones or pulses to dial an electronic receiver such as a |
|
|
| monitoring station, mobile phone, or pocket pager. It uses the public switched |
|
|
| telephone network to send alarm or supervisory signals. |
|
| disarmed | A system status that does not accept alarms, except for |
|
| dual reporting | Reporting that allows your control panel to transmit alarm signals in two different |
|
|
| reporting formats (for example, the control panel can transmit to a monitoring station |
|
|
| and to a mobile phone, or to two different monitoring stations). |
|
| dynamic battery | A method used to monitor and test the condition of your backup battery. |
|
| testing |
|
|
| EDMSAT satellite | A |
|
| siren | battery that provides a higher level of security for an alarm system. |
|
| entry delay | A programmed delay of the system alarm responses that allows a person to enter a |
|
|
| building through the entry door to turn the system off. |
|
| entry warning | The beeping from a codepad during an entry delay as a reminder to disarm the system. |
|
| exit delay | A programmed delay of the system alarm responses that allows a person to leave a |
|
|
| building after turning the system on. |
|
| external equipment | Any device connected to a security system, such as a detector, codepad, or siren. |
|
| force arming | A method of overriding the safety feature that prevents arming with a faulted zone on a |
|
|
| control panel. |
|
|
| If a system is armed and Zone 1 is violated, the entry delay starts timing. If Zone 2 is |
|
|
| violated, the entry delay time is handed over to the Zone 2 and so on, to Zones 3 and |
|
|
| 4. This is known as sequential |
|
| A device used to arm and disarm a security system or to cause a panic alarm. |
| |
| remote control |
|
|
| lockout dialer | A dialer that activates only once per zone per arming cycle. |
|
| lockout siren | A siren that activates only once per zone per arming cycle. |
|
|
|
|
|
|
|
|
|
| Bosch Security Systems, Inc. 12/08 | 79 |