2.4.3Command 960 – Exit from the Installer's Programming Mode

ICP-CC404 Installation Guide 2.0 Programming

2.4.3Command 960 – Exit from the Installer's Programming Mode

This command exits from the Installer’s Programming Mode. You can exit from the Installer’s Programming Mode from any location.

To exit from the Installer’s Programming Mode:

Enter [9 6 0 #].

Two beeps sound and the system returns to the disarmed state. When using the remote codepad, the STAY and AWAY indicators turn off.

2.4.4Command 961 – Reset the Control Panel to Factory Default Settings

This command resets the control panel to factory default values. Default values are listed throughout this guide and in the programming sheets in Section 22.0 on page 85. You can reset the control panel from any location.

To reset the control panel to factory defaults:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the remote codepad to indicate you entered Installer’s Programming Mode. The remote codepad shows the data stored in Location 000.

2.Enter [9 6 1 #].

Two beeps sound and the system resets to the factory default values.

2.4.5Command 962 – Copy the Control Panel Memory to the Programming Key

This command copies the control panel memory to the programming key. You can only use the CC891 Programming Key with the ICP-CC404 Control Panel.

To copy the control panel memory to the programming key:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the remote codepad to indicate you entered Installer’s Programming Mode. The remote codepad shows the data stored in Location 000.

2.Connect the programming key to the PROGRAMMING KEY pins (next to the Auxiliary Module socket) at the top of the control panel’s printed circuit board.

3.Enter [9 6 2 #].

Two beeps sound after the control panel memory is successfully copied to the programming key. A long beep indicates that the programming key is corrupt and must be erased to clear the corrupt data. Refer to Section 2.4.7 Command 964 – Erase the Programming Key on page 13 for more information.

4.Enter command [9 6 0 #] to exit from the Installer’s Programming Mode.

The STAY and AWAY indicators turn off on the remote codepad to indicate that the system is disarmed.

5.Remove the programming key from the control panel.

Failure to exit from the Installer’s Programming Mode before removing the programming key can corrupt the programming key.

2.4.6Command 963 – Copy the Programming Key to the Control Panel

This command copies data from the programming key to the control panel. You can only use the CC891 Programming Key with the ICP-CC404 Control Panel.

To copy the programming key memory to the control panel:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the remote codepad to indicate you entered Installer’s Programming Mode. The remote codepad shows the data stored in Location 000.

2.Connect the programming key to the PROGRAMMING KEY pins (next to the Auxiliary Module socket) at the top of the control panel’s printed circuit board.

3.Enter [9 6 3 #].

Two beeps sound after the programming key’s data is successfully copied to the control panel. A long beep indicates that the programming key is corrupt and must be erased to clear the corrupt data. Refer to Section 2.4.7 Command 964 – Erase the Programming Key on page 13 for more information.

4.Enter [9 6 0 #] to exit from the Installer’s Programming Mode.

The STAY and AWAY indicators turn off on the remote codepad to indicate that the system is disarmed.

5.Remove the programming key from the control panel.

Failing to exit from the Installer’s Programming Mode before removing the programming key can corrupt the programming key.