11.6Dialing Format

ICP-CC404 Installation Guide 11.0 Dialer Information

When using Domestic Dialing Format, the number of identification beeps is determined by the value programmed in Location 039 (Receiver 1) and Location 079 (Receiver 2). This value allows the identification of up to 15 different control panels that call the same telephone number.

Example

To program the Subscriber ID Number as 4729, program:

0 0 4 7 2 9

11.6Dialing Format

Program the Dialing Format in Location 080.

The default value for the Dialing Format is 1.

The Dialing Format determines the method for dialing telephone numbers. The options are:

1 – Australian DTMF (5 digits/sec)

2 – Australian decadic

3 – Alternate DTMF and Australian decadic

4 – International DTMF (touch tone)

5 – Reversed decadic (10 minus 1)

6 – Alternate DTMF and reversed decadic

Options 3 and 6 alternate the dialing sequence between DTMF and decadic if the call to the base station receiver is unsuccessful. Use caution when selecting the dialing method.

Select the Australian method only if the control panel is connected to the Australian Telecommunications Network. Select the International DTMF dialing option only in countries that allow both the caller and the receiver to terminate a phone call. Using the incorrect format can disable the control panel’s patented Telephone Anti-Jamming feature.

The alternating sequence is: DTMF – decadic – DTMF – decadic – DTMF – decadic.

Table 39: Telco Arm or Disarm Dialing Digits

 

 

 

 

Digit

Number to

Digit

Number to

Required

Program

Required

Program

terminator

0

8

8

1

1

9

9

2

2

0

10

3

3

*

11

4

4

#

12

5

5

4 sec pause

13

6

6

break

14

7

7

 

 

When the Telco Arming Sequence is activated after arming the system in AWAY Mode, the control panel redirects all calls to your mobile phone, pocket pager, or answering service.

Contact your telecommunications provider for more information on Call Forward operations.

To turn call forward (immediate) on, enter:

[* 2 1][forwarding telephone number][#]

Example

To immediately forward all incoming calls to the telephone number 96721055 after arming the system in AWAY Mode, program:

[11

2 1 9 6

7 2 1

10

5 5

12

0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0]

 

 

 

 

 

To turn call forward (no answer) on, enter:

[* 6 1][forwarding telephone number][#]

Example

To forward all incoming calls, when there is no answer, to the telephone number 96721055 after arming the system in AWAY Mode, program:

[11

6 1 9 6

7 2 1

10

5 5

12

0 0 0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0]

 

 

 

 

 

11.7Telco Arming Sequence

Program the Telco Arming Sequence in Locations 113 to 142.

The default value for the Telco Arming Sequence is

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.

These locations allow you to activate call diversion automatically on your telephone when you arm the system in AWAY Mode. Refer to Table 39.

11.8Telco Disarming Sequence

Program the Telco Disarming Sequence in Locations 143 to 158.

The default value for the Telco Disarming Sequence is 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.

This parameter allows you to deactivate call diversion automatically on your telephone when you disarm the system from AWAY Mode. Refer to Table 39.

To turn call forward (immediate) off, enter:

[# 2 1 #]

Example

To disable call forward (immediate) after disarming the system from AWAY Mode, program:

[12 2 1 12 0 0 0 0 0 0 0 0 0 0 0 0]