Electric Shock Hazard
Electrical Grounding is required on this appliance.
Do Not connect to the electrical supply until the appliance is permanently grounded.
Disconnect the power to the junction box before making the electrical connection.
This appliance must be connected to a grounded, metallic, permanent supply or a
grounding connector should be connected to the grounding terminal or wire lead on the
appliance.
Do Not ground to gas pipe. Failure to follow these instructions could result in death or
serious injury.
zA four-wire single phase 240-volt, 60-Hz, AC-only electrical supply is required on a
separate circuit, fused on both sides of the line.
zA time-delay fuse or circuit breaker is recommended.
zIf local codes permit, use a U.L. listed, 250-volt, 30-amperes power cord (pigtail). This cord
contains four No. 10 copper wires and matches a four-wire receptacle of type 14-30R.
Connectors on the appliance end must be provided at the point the power supply enters
the appliance.
Wires sizes (COPPER WIRE ONLY) and connections must conform with the rating of range
(30-amperes).
zThe wiring diagram is located on the back of the appliance.
THIS APPLIANCE MUST HAVE THE FACILITYOF BEING COMPLETELY ISOLATED
FROM THE ELECTRICITY SUPPLY.
THE APPLIANCE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY
SUPPLYBEFORE SERVICING.
7
ELECTRICAL CONNECTION