Stud

Drywall/sheetrock

Mounting tabs for NXD Wall Mount panel should be flush with the outside of the sheetrock

Installation Procedures: 17" Panels

Inserted block bridges the gap between the Conduit Box and the notched beam

Knockouts should be located on the left-side of the conduit box, alongside the connectors

Stud fastening holes

Conduit Box can be fastened to both studs)

Use four #8 flat-head Mounting Screws to secure the NXD to the CB

Secure Beam to block

Depth depends on the thickness of the Drywall

Notched stud

FIG. 56 Screw locations for conduit box attachment in a pre-wall installation

Installation of an NXD-1700VG

The NXD-1700VG can be installed either directly into the (optional) CB-TP17 or other solid surface environment using the two different mounting options: drywall clips or solid surface screws. The following sections describe mounting the touch panel directly into an installed pre-wall Conduit Box, a solid surface or drywall, and optional NXA-RK17 Rack Mount Kit.

Installing the NXD-1700VG within a CB-TP17 Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the Pre-wall Installation of the CB-TP17 Conduit Box section on page 75 for detailed pre-wall installation instructions. Verify that all necessary cables have been threaded through the knockouts on the conduit box and the connections have been tested prior to installation of the NXD-1700VG.

1.Remove the magnetic faceplate/bezel (A in FIG. 57) from the main NXD unit (B in FIG. 57) by gripping the faceplate and pulling with gentle outward force.

2.Verify the incoming RJ-45, Ethernet, and any other audio/video cables have been properly threaded through the wiring knockouts on the left of the conduit box. Leave enough slack in the wiring to accommodate any re-positioning of the panel.

3.Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch panel.

Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power connector.

The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.

VG-Series Modero Touch Panels