Displaying Stream Content

Determine what is the available data rate for the network on which the encoder currently resides. This information will determine what encoder profile can be used on the outgoing media content. If the network can only handle a throughput of 4 Mbps from the encoder, it is recommended that you use something less than or equal to the High Quality encoder profile.

Setting up a Modero Panel to Receive and Display a Stream

The MAX-CSE must first be prepared to stream to the target Modero panel prior to creating the necessary TPDesign4 panel pages (later be uploaded to the panel).

Step 1: Obtaining the IP Address of the target panel

1.Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 127).

Connection Status

Red Connection Status icon - indicates no connection to a Master

Green Connection Status icon - indicates communication to a Master

FIG. 127 Setup page

2.Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and display an on-screen keypad.

3.Enter 1988 into the Keypad’s password field and press Done when finished.

4.Press the System Settings button (located on the Protected Setup page) to open the System Settings page and obtain the IP information from the IP Address field (FIG. 128).

Modero IP Address information

FIG. 128 System Settings page

VG-Series Modero Touch Panels

171

 

 

Page 181
Image 181