Touch Panel Accessories

The following table provides the wiring information for each of the four (4) available connectors on each side of the NXA-MTC/RGB Tabletop Cable.

Wire Table

Wire

Connector 1

Connector 2

Connector 3

Connector 4

 

 

 

 

 

1

White/Orange

White/Orange

Red

White/Orange

 

 

 

 

 

2

Orange/White

Orange/White

Black

Orange/White

 

 

 

 

 

3

White/Green

White/Green

-

White/Green

 

 

 

 

 

4

Blue/White

Blue/White

-

Blue/White

 

 

 

 

 

5

White/Blue

White/Blue

-

White/Blue

 

 

 

 

 

6

Green/White

Green/White

-

Green/White

 

 

 

 

 

7

White/Brown

White/Brown

-

White/Brown

 

 

 

 

 

8

Brown/White

Brown/White

-

Brown/White

 

 

 

 

 

Installing CAT5 Suppression Ferrites

Before connecting the RJ-45 cables to the Modero Touch Panel, install the necessary number of CAT5 Suppression Ferrites (FIG. 10) to the RJ-45 Audio/Video cable. These ferrites come as part of the Installation Kits mentioned in the previous Specification table (page 28).

No tools are required for this installation.

Release the latch to

Insert the CAT5

Push down on the

open the plastic

cable and close

enclosure until it

enclosure.

the enclosure.

snaps closed.

 

FIG. 10 Installing the CAT5 Suppression Ferrites

All 1200V-Series, VG-Series, and Table Top CV10 panels require the installation of an appropriate number of CAT5 Suppression Ferrites when they use an RJ-45 cable to feed an A/V signal from the breakout box.

1.The CAT5 Suppression Ferrite is housed within a plastic enclosure (shown in FIG. 10) with a latch release on one side. Pull to release the latch and open the enclosure.

2.Grasp the Black RJ-45 Audio/Video cable being connected to the panel. This end of the cable is longer than the opposing end which connects to the breakout box (6 inches vs 3 inches).

Refer to FIG. 11 for more detailed information.

3.Insert the panel-end of the Black RJ-45 Audio/Video cable into the groove along the inside of the enclosure.

The CAT5 Suppression Ferrites MUST be installed onto the cable connected to the

Modero’s Audio/Video RJ-45 connector (just behind the connector).

4.Snap the enclosure shut with the cable inside, and you’re done.