Programming

"^" Button Commands (Cont.)

^BSO

If the sound name is blank the sound is then cleared. If the sound name is not matched,

Set the sound

the button sound is not changed.

 

played when a

Syntax:

button is pressed.

"'^BSO-<vt addr range>,<button states range>,<sound name>'"

 

 

Variable:

 

variable text address range = 1 - 4000.

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

sound name = (blank - sound cleared, not matched - button sound not changed).

 

Example:

 

SEND_COMMAND Panel,"'^BSO-500,1&2,music.wav'"

 

Assigns the sound 'music.wav' to the button Off/On states.

 

 

^BVL

Syntax:

Log-On/Log-Off

"'^BVL-<vt addr range>,<connection>'"

the computer

Variable:

control

variable text address range = 1 - 4000.

connection.

connection = 0 (Log-Off connection) and 1 (Log-On connection).

 

 

Example:

 

SEND_COMMAND Panel,"'^BVL-500,0'"

 

Logs-off the computer control connection of the button.

 

 

^BVN

Syntax:

Set the computer

SEND_COMMAND <DEV>,"'^BVN-<vt addr range>,<remote host>'"

control remote

Variables:

host for the

variable text address range = 1 - 4000.

specified address.

remote host = 1 - 50 ASCII characters.

 

 

Example:

 

SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"

 

Sets the remote host to '191.191.191.191' for the specific computer control button.

 

 

^BVP

Syntax:

Set the network

"'^BVP-<vt addr range>,<network password>'"

password for the

Variable:

specified address.

variable text address range = 1 - 4000.

 

 

network password = 1 - 50 ASCII characters.

 

Example:

 

SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"

 

Sets the password to PCLOCK for the specific PC control button.

 

 

^BVT

Syntax:

Set the computer

"'^BVT-<vt addr range>,<network port>'"

control network

Variable:

port for the

variable text address range = 1 - 4000.

specified address.

 

 

network port = 1 - 65535.

 

Example:

 

SEND_COMMAND Panel,"'^BVT-500,5000'"

 

Sets the network port to 5000.

 

 