Firmware Pages and Descriptions

Sensor Setup Page

The Sensor Setup page (FIG. 122) allows you to adjust the Light and Motion Sensor parameters on a Modero touch panel.

FIG. 122 Sensor Setup page

A light level value between the Minimum and Maximum DIM Mode values delivers an average light level. The DIM mode Min Level can never exceed the DIM Mode Max Level.

The elements of the Sensor Setup page are described in the table below:

Sensor Setup Page Elements

Back:

Saves the changes and returns you to the previously active touch panel page.

 

 

Connection Status icon:

This visual display of the connection status allows the user to have a current

 

visual update of the panel’s connection status regardless of what page is

 

currently active.

 

• A Lock only appears on the icon if the panel has established a connection

 

with a currently secured target Master (requiring a username and password).

 

 

Light Sensor:

Allows you to monitor and alter the sensitivity of the Modero panel light sensor:

 

• The Light Sensor Level field indicates the level used to report the light

 

sensor level back to the NetLinx Master (set in TPD4) (read-only).

 

• The Light Sensor Level Port field indicates the port used to report the light

 

sensor level back to the NetLinx Master (set in TPD4) (read-only).

 

• The Light Sensor Channel field indicates the level used to report the sensor

 

channel back to the NetLinx Master (set in TPD4). It is On when you are

 

below the Maximum dim mode level (read-only).

 

• The Light Sensor Channel Port field indicates the port used to report the

 

sensor channel back to the NetLinx Master (set in TPD4) (read-only).

 

• The Light Level field provides a numeric value representing the current value

 

of the light level detected by the on-board photo-sensor.

 

• The Light Level bargraph displays a horizontal bargraph indicating the current

 

value of the light level detected by the on-board photo-sensor. This bargraph

 

provides a visual representation of the numeric value displayed within the

 

Light Level field.

 

• Use the Dim Mode Max Level bargraph to alter the Maximum DIM level

 

value used to activate the DIM Mode Brightness Level (range = 0 - 100).

 

• Use the Dim Mode Min Level bargraph to alter the Minimum DIM level value

 

used to activate the DIM Mode Brightness Level (range = 0 - 100).

 

- The position of this bargraph can never exceed that of the Dim Mode

 

Max Level.

 

 

158

VG-Series Modero Touch Panels

Page 168
Image 168
AMX NXD/NXT-1500VG, NXD/NXT-1700VG, NXD/NXT-1200VG manual Sensor Setup Page Elements, Light Sensor, Light Level field