Configuring Communication

Master Connection section - NetLinx Master Ethernet IP Address - URL Mode

In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master (Master Port Number is defaulted to 1319).

1.Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet. Refer to the System Settings Page section on page 166 for more information about the fields on this page.

2.Press the Mode field until the choice cycles to the word URL.

By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value directly from the communicating target Master (virtual or not). A Virtual Master system value can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.

If the panel does not appear within the OnLine Tree tab of the Workspace window of NetLinx Studio, check to make sure that the NetLinx Master System Number (from within the Device Addressing dialog) is correctly assigned.

3.Press the Master IP/URL field to open a Keyboard and enter the Master IP Address (obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio application).

4.Click Done to accept the new value and return to the System Settings page.

5.Do not alter the Master Port Number value (this is the default value used by NetLinx).

6.Enter a username and password (into their respective fields) if the target Master has been previously secured.

7.Press the Back button to open the Protected Setup page.

8.Press the on-screen Reboot button to both save any changes and restart the panel.

Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode

In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL list).

1.Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address from the IP Settings of the System Settings page.

The DHCP/Static field (in the IP Settings section of the System Settings page) must be set to DHCP to get Dynamic IP information for the panel.

Press the on-screen Reboot (from the Protected Setup page) to both save any changes and restart the panel.

After power-up, press the grey Front Setup Access button for 3 seconds to access the Setup page.

Navigate to the Setup > Protected Setup > System Settings page and note the newly obtained Dynamic IP Address information from the IP Settings section. This information is then entered into the URL List for the connected NetLinx Master.

2.Toggle the blue Type field until Ethernet is selected (from the Master Connection section of the System Settings page).

3.Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen.

4.Enter a username and password (into their respective fields) if the target Master has been previously secured.

5.Select the OnLine Tree tab from the Workspace window.

114

VG-Series Modero Touch Panels

Page 124
Image 124
AMX NXD/NXT-1700VG, NXD/NXT-1500VG, NXD/NXT-1200VG manual 114