Troubleshooting

Troubleshooting Information (Cont.)

Symptom

Solution

 

 

After downloading a panel file or

Symptoms include:

firmware to a G4 device, the panel

• Having to repeat the download.

behaves strangely.

• Inability to make further downloads to the panel. May get "directory"

 

 

errors, "graphics hierarchy" errors, etc.… indicating problems with

 

the Compact Flash.

 

• Panel will not boot, or gets stuck on "AMX" splash screen.

 

• Other problems also started after downloading to a new panel or a

 

panel with a TPD4 file that takes up a considerable amount of the

 

available Compact Flash.

 

Cause:

 

• If the G4 device already contains a large enough file, subsequent

 

downloads will take up more space than is available and could often

 

corrupt the Compact Flash. The demo file that typically ships with G4

 

panels is one such file.

 

Solution:

 

• DO NOT download TPD4 files (of large size) over the demo pages, or

 

any other large TPD4 file.

 

• First download a small blank one page file to the G4 panel using the

 

Normal Transfer option to send/download the page. Reboot the

 

device, then do your regular file or firmware download.

 

 

My NXA-BASE/B Battery Base

The battery base CAN NOT be "hot swapped". This swapping

isn’t being recognized by the NXT

occurs when an NXT panel is currently being powered by a PSN6.5

touch panel.

and then is connected to a battery base containing NXT-BP batteries.

 

Introducing a new power source onto an existing configuration can

 

damage the NXA-BASE.

 

Solution:

 

If your base is not being recognized by the touch panel but is still

 

providing power:

 

• Launch the latest NetLinx Studio.

 

• Refresh the particular System from within the OnLine Tree tab.

 

• Identify the NXT panel using the battery base.

 

• From the Main menu go to Tools > Firmware Transfers > Send to

 

NetLinx Device.

 

• Locate and select the 2250_XXX_v2 KIT file for the battery base.

 

• Enter the Device and System values, verify the method of

 

communication (IP recommended).

 

• Click Send to reload the new base KIT file onto the NXA-BASE/B.

 

If this above steps do not cause the base to be recognized by the NXT

 

touch panel on the Setup page, contact AMX Technical Support for

 

further assistance.

 

 

The Battery Base button doesn’t

• Refer to the above troubleshooting symptom.

appear on the panel’s Setup page.

 

 

 

My RGB image looks blurry. The

• Refer to the Adjusting the Incoming Signal on the RGB Adjustment

edges of the characters appear

Page section on page 145 for more detailed information on adjusting

shadowed and/or blurry.

the skew of the incoming image.

 

 

234

VG-Series Modero Touch Panels

Page 244
Image 244
AMX NXD/NXT-1700VG Symptom Solution After downloading a panel file or, Behaves strangely, Touch panel, NetLinx Device