Installation Procedures: 17" Panels

Stud

 

Support block

C - Optional CB-TP17

 

conduit/wallbox

Four #8 flat-head

Mounting ScrewsMounting Tab (not included)

secure the NXD to the Conduit Box

Do not use these tabs to mount the conduit /wallbox These are ONLY used to

secure the main unit to the CB

A - Faceplate

B - Main NXD unit consists of

the touch panel and backbox housing

(bezel)

FIG. 57 Wall Mount panel installation configuration of a CB-TP17 in a pre-wall construction

4.Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify the panel is receiving power and functioning properly to prevent repetition of the installation.

5.Disconnect the terminal end of the power cable from the connected power supply.

Don’t disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before being inserted into the conduit box.

6.Carefully slide the main NXD unit (B in FIG. 57) into the conduit box, so the Mounting Tab lies flush against the conduit box (C in FIG. 57).

7.Insert and secure four securing #8 flat-head Mounting Screws into their corresponding holes located along the sides of the NXD (FIG. 57). These #8 screws are not included within the CB Installation Kit and must be provided by the installer.

8.Place the magnetic faceplate (A in FIG. 57) back onto the main NXD unit (B in FIG. 57). Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front bezel/faceplate.

9.Reconnect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective locations (outside the conduit box) on either the NXA-AVB/RGB, Ethernet port, or NetLinx Master.

10.Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.