Upgrading Modero Firmware

Upgrading the NXA-RGB and NXA-AVB/RGB Firmware

1.Identify the Device number of the target panel being used for firmware routing to the accessories.

2.Complete the instructions for configuring the NetLinx Master for IP communication found in the Step 1: Prepare the Master for communication via an IP section on page 125.

3.Press the grey Front Setup Access button for 3 seconds to open the Setup page.

4.Press the Video Adjustment > RGB Adjustment buttons to open the RGB Adjustment page (FIG. 102). This page displays the firmware for both the internal NXA-RGB card and the communicating external NXA-AVB/RGB Breakout Box (BOB).

Firmware version of the NXA-RGB card

Firmware version of the NXA-AVB/RGB

Incoming signal shown in the background

FIG. 102 RGB Adjustment page (showing the default values)

5.Follow the procedures outlined within the Step 2: Upgrade the NXA-BASE/B firmware via an IP section on page 130.

If firmware is updated to either the panel or the breakout box, both units must be power-cycled for the panel to detect and display the new BOB firmware version.

132

VG-Series Modero Touch Panels

Page 142
Image 142
AMX NXD/NXT-1700VG manual Upgrading the NXA-RGB and NXA-AVB/RGB Firmware, RGB Adjustment page showing the default values