Installation Procedures: 12" and 15" Panels

CUTOUT

FRONT BEZEL

FIG. 40 NXD-1200VG 12-inch Wall Mount panel dimensions using expansion clips

3.Remove the magnetic faceplate/bezel (A in FIG. 42) from the main NXD unit (B in FIG. 42) by gripping the faceplate and pulling with gentle outward force.

4.Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal locations) through the cutout opening. Refer to the Wiring Guidelines for the 1200VG and 1500VG Panels section on page 68 for pinout descriptions. Leave enough slack in the wiring to accommodate any re-positioning of the panel.

5.Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch panel.

Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power connector.

The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.

6.Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify the panel is receiving power and functioning properly to prevent repetition of the installation.

7.Disconnect the terminal end of the power cable from the connected power supply.

VG-Series Modero Touch Panels

61

 

 

Page 71
Image 71
AMX NXD/NXT-1200VG, NXD/NXT-1500VG, NXD/NXT-1700VG manual Cutout Front Bezel